Show simple item record

contributor authorEi Yamamoto
contributor authorDaisuke Kogawa
contributor authorSusumu Tokura
contributor authorKozaburo Hayashi
date accessioned2017-05-09T00:15:11Z
date available2017-05-09T00:15:11Z
date copyrightDecember, 2005
date issued2005
identifier issn0148-0731
identifier otherJBENDY-26573#1168_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/131294
description abstractThe effects of frequency or duration of cyclic stress on the mechanical properties of collagen fascicles were studied by means of in vitro tissue culture experiments. Collagen fascicles of approximately 300μm in diameter were obtained from rabbit patellar tendons. During culture, cyclic stress having the peak stress of approximately 2MPa was applied to the fascicles at 1Hz for 1hour∕day (1Hz-1h group), at 1Hz for 4hours∕day (1Hz-4h group), or at 4Hz for 1hour∕day (4Hz-1h group). The frequency of 4Hz and the duration of 1hour∕day are considered to be similar to those of the in vivo stress applied to fascicles in the intact rabbit patellar tendon. After culture for 1 or 2weeks, the mechanical properties of the fascicles were determined using a micro-tensile tester, and were compared to the properties of non-cultured, fresh fascicles (control group) and the fascicles cultured under no load condition (non-loaded group). The tangent modulus and tensile strength of fascicles in the 4Hz-1h group were similar to those in the control group; however, the fascicles of the 1Hz-1h and 1Hz-4h groups had significantly lower values than those of the control group. There was no significant difference in the tensile strength between the 1Hz-1h and non-loaded groups, although the strength in the 1Hz-4h group was significantly higher than that of the non-loaded group. It was concluded that the frequency and duration of cyclic stress significantly affect the mechanical properties of cultured collagen fascicles. If we apply cyclic stress having the frequency and duration which are experienced in vivo, the biomechanical properties are maintained at control, normal level. Lower frequencies or less cycles of applied force induce adverse effects.
publisherThe American Society of Mechanical Engineers (ASME)
titleEffects of the Frequency and Duration of Cyclic Stress on the Mechanical Properties of Cultured Collagen Fascicles From the Rabbit Patellar Tendon
typeJournal Paper
journal volume127
journal issue7
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2073587
journal fristpage1168
journal lastpage1175
identifier eissn1528-8951
keywordsStress
keywordsBiomechanics
keywordsMechanical properties
keywordsTendons AND Biological tissues
treeJournal of Biomechanical Engineering:;2005:;volume( 127 ):;issue: 007
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record