| contributor author | Ei Yamamoto | |
| contributor author | Daisuke Kogawa | |
| contributor author | Susumu Tokura | |
| contributor author | Kozaburo Hayashi | |
| date accessioned | 2017-05-09T00:15:11Z | |
| date available | 2017-05-09T00:15:11Z | |
| date copyright | December, 2005 | |
| date issued | 2005 | |
| identifier issn | 0148-0731 | |
| identifier other | JBENDY-26573#1168_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/131294 | |
| description abstract | The effects of frequency or duration of cyclic stress on the mechanical properties of collagen fascicles were studied by means of in vitro tissue culture experiments. Collagen fascicles of approximately 300μm in diameter were obtained from rabbit patellar tendons. During culture, cyclic stress having the peak stress of approximately 2MPa was applied to the fascicles at 1Hz for 1hour∕day (1Hz-1h group), at 1Hz for 4hours∕day (1Hz-4h group), or at 4Hz for 1hour∕day (4Hz-1h group). The frequency of 4Hz and the duration of 1hour∕day are considered to be similar to those of the in vivo stress applied to fascicles in the intact rabbit patellar tendon. After culture for 1 or 2weeks, the mechanical properties of the fascicles were determined using a micro-tensile tester, and were compared to the properties of non-cultured, fresh fascicles (control group) and the fascicles cultured under no load condition (non-loaded group). The tangent modulus and tensile strength of fascicles in the 4Hz-1h group were similar to those in the control group; however, the fascicles of the 1Hz-1h and 1Hz-4h groups had significantly lower values than those of the control group. There was no significant difference in the tensile strength between the 1Hz-1h and non-loaded groups, although the strength in the 1Hz-4h group was significantly higher than that of the non-loaded group. It was concluded that the frequency and duration of cyclic stress significantly affect the mechanical properties of cultured collagen fascicles. If we apply cyclic stress having the frequency and duration which are experienced in vivo, the biomechanical properties are maintained at control, normal level. Lower frequencies or less cycles of applied force induce adverse effects. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Effects of the Frequency and Duration of Cyclic Stress on the Mechanical Properties of Cultured Collagen Fascicles From the Rabbit Patellar Tendon | |
| type | Journal Paper | |
| journal volume | 127 | |
| journal issue | 7 | |
| journal title | Journal of Biomechanical Engineering | |
| identifier doi | 10.1115/1.2073587 | |
| journal fristpage | 1168 | |
| journal lastpage | 1175 | |
| identifier eissn | 1528-8951 | |
| keywords | Stress | |
| keywords | Biomechanics | |
| keywords | Mechanical properties | |
| keywords | Tendons AND Biological tissues | |
| tree | Journal of Biomechanical Engineering:;2005:;volume( 127 ):;issue: 007 | |
| contenttype | Fulltext | |