description abstractA tapered interference fit provides a mechanically reliable retention mechanism for the implant-abutment interface in a dental implant. Understanding the mechanical properties of the tapered interface with or without a screw at the bottom has been the subject of a considerable amount of studies involving experiments and finite element (FE) analysis. In this paper, approximate closed-form formulas are developed to analyze the mechanics of a tapered interference fit. In particular, the insertion force, the efficiency, defined as the ratio of the pull-out force to insertion force, and the critical insertion depth, which causes the onset of plastic deformation, are analyzed. It is shown that the insertion force is a function of the taper angle, the contact length, the inner and outer radii of the implant, the static and the kinetic coefficients of friction, and the elastic modulii of the implant/abutment materials. The efficiency of the tapered interference fit, which is defined as the ratio of the pull-out force to insertion force, is found to be greater than one, for taper angles that are less than 6 deg when the friction coefficient is 0.3. A safe range of insertion forces has been shown to exist. The lower end of this range depends on the maximum pull-out force that may occur due to occlusion in the multiple tooth restorations and the efficiency of the system; and the upper end of this range depends on the plastic deformation of the abutment and the implant due to interference fit. It has been shown that using a small taper angle and a long contact length widens the safe range of insertion forces.
publisherThe American Society of Mechanical Engineers (ASME)
titleEfficiency Considerations for the Purely Tapered Interference Fit (TIF) Abutments Used in Dental Implants
typeJournal Paper
journal volume126
journal issue4
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.1784473
journal fristpage393
journal lastpage401
identifier eissn1528-8951
keywordsForce
keywordsFriction
keywordsFormulas
keywordsDesign
keywordsDeformation AND Mechanisms
treeJournal of Biomechanical Engineering:;2004:;volume( 126 ):;issue: 004