Show simple item record

contributor authorMahendra D. Rana
contributor authorOwen Hedden
contributor authorDave Cowfer
contributor authorRoger Boyce
date accessioned2017-05-09T00:05:45Z
date available2017-05-09T00:05:45Z
date copyrightAugust, 2001
date issued2001
identifier issn0094-9930
identifier otherJPVTAS-28410#338_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/125736
description abstractIn 1996, Code Case 2235, which allows ultrasonic examination of welds in lieu of radiography for ASME Section VIII Division 1 and Division 2 vessels, was approved by the ASME B&PV Code Committee. This Code Case has been revised to incorporate: 1) a reduction in minimum usable thickness from 4″ (107.6 mm) to 0.5″ (12.7 mm), and 2) flaw acceptance criteria including rules on multiple flaws. A linear elastic fracture mechanics procedure has been used in developing the flaw acceptance criteria. This paper presents the technical basis for Code Case 2235.
publisherThe American Society of Mechanical Engineers (ASME)
titleTechnical Basis for ASME Section VIII Code Case 2235 on Ultrasonic Examination of Welds in Lieu of Radiography
typeJournal Paper
journal volume123
journal issue3
journal titleJournal of Pressure Vessel Technology
identifier doi10.1115/1.1376719
journal fristpage338
journal lastpage345
identifier eissn1528-8978
keywordsWelded joints
keywordsAcceptance criteria
keywordsThickness
keywordsVessels
keywordsFracture (Process)
keywordsSizing (Textile treatment)
keywordsFracture mechanics AND Construction
treeJournal of Pressure Vessel Technology:;2001:;volume( 123 ):;issue: 003
contenttypeFulltext