Show simple item record

contributor authorP. W. Longest
contributor authorJ. S. Kinsey
contributor authorEnvironmental Engineer
contributor authorC. Kleinstreuer
date accessioned2017-05-09T00:02:44Z
date available2017-05-09T00:02:44Z
date copyrightJune, 2000
date issued2000
identifier issn0098-2202
identifier otherJFEGA4-27151#403_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/123895
description abstractSteady incompressible turbulent air flow and transient carbon monoxide transport in an empty Rochester-style human exposure chamber have been numerically simulated and compared with experimental data sets. The system consisted of an inlet duct with a continuous carbon monoxide point source, 45- and 90-degree bends, a round diffuser, a round-to-square transition, a rectangular diffuser, the test chamber, a perforated floor, and again transition pieces from the chamber to an outlet duct. Such a configuration induced highly nonuniform vortical flow patterns in the chamber test area where a pollutant concentration is required to be constant at breathing level for safe and accurate inhalation studies. Presented are validated momentum and mass transfer results for this large-scale system with the main goals of determining the development of tracer gas (CO) distributions in the chamber and analyzing the contributions to CO-mixing. Numerical simulations were conducted employing a k-ε model and the latest available RNG k-ε model for air and CO-mixing. Both models predict similar velocity fields and are in good agreement with measured steady and transient CO-concentrations. It was found that secondary flows in the inlet section and strong vortical flow in the chamber with perforated flooring contributed to effective mixing of the trace gas at breathing levels. Specifically, in the height range of 1.4 m<h<2.0 m above the chamber floor, predicted CO-concentrations rapidly reached a near constant value which agrees well with experimental results. This work can be extended to analyze trace gas mixing as well as aerosol dispersion in occupied test chambers with or without flow redirection devices installed in the upstream section. A complementary application is particle transport and deposition in clean rooms of the electronic, pharmaceutical, and health care industries. [S0098-2202(00)01702-8]
publisherThe American Society of Mechanical Engineers (ASME)
titleTurbulent Three-Dimensional Air Flow and Trace Gas Distribution in an Inhalation Test Chamber
typeJournal Paper
journal volume122
journal issue2
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.483270
journal fristpage403
journal lastpage411
identifier eissn1528-901X
keywordsFlow (Dynamics)
keywordsTurbulence
keywordsAir flow
keywordsDucts
keywordsPollution
keywordsDiffusers
keywordsComputer simulation AND Vortex flow
treeJournal of Fluids Engineering:;2000:;volume( 122 ):;issue: 002
contenttypeFulltext