Show simple item record

contributor authorDaniel O. Baun
contributor authorGraduate Research Assistant and ROMAC Lab Engineer
contributor authorLutz Köstner
contributor authorProject Engineer
contributor authorRonald D. Flack
contributor authorProfessor and Department Head
date accessioned2017-05-09T00:02:41Z
date available2017-05-09T00:02:41Z
date copyrightSeptember, 2000
date issued2000
identifier issn0098-2202
identifier otherJFEGA4-27154#598_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/123865
description abstractThe hydraulic performance and radial hydraulic force characteristics of a circular volute centrifugal pump are strongly affected by the impeller to volute relative position. For a typical design configuration the geometric center of the impeller will be coincident with the volute geometric center. However, assembling a circular volute pump with the impeller center eccentric from the volute center can radically alter both the hydraulic performance and the radial hydraulic force characteristics. In particular, at the design flow coefficient an optimum impeller to volute relative position exists where the efficiency is maximized and the resultant radial force is minimized. At the optimal relative position a 5 percent and a 3.5 percent increase in the efficiency was realized compared to the centered positions for the circular and spiral volutes, respectively. In addition the nondimensional resultant radial force at the design flow coefficient was reduced from 0.045 at the centered position to 0.005 at the optimal position for the circular casing. This value of radial thrust is similar in magnitude to the radial thrust for the spiral volute operating at the design flow coefficient. By assembling a circular volute pump with the appropriate relative impeller to volute position the design simplicity of a circular volute can be utilized without compromising pump hydraulic performance or radial force characteristics as compared to a typical spiral volute. [S0098-2202(00)02303-8]
publisherThe American Society of Mechanical Engineers (ASME)
titleEffect of Relative Impeller-to-Volute Position on Hydraulic Efficiency and Static Radial Force Distribution in a Circular Volute Centrifugal Pump
typeJournal Paper
journal volume122
journal issue3
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.1287852
journal fristpage598
journal lastpage605
identifier eissn1528-901X
keywordsForce
keywordsFlow (Dynamics)
keywordsImpellers
keywordsCentrifugal pumps
keywordsPumps AND Design
treeJournal of Fluids Engineering:;2000:;volume( 122 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record