Show simple item record

contributor authorG. R. Price
contributor authorS. N. Rizopoulos
contributor authorH. Golshan
contributor authorR. K. McBrien
date accessioned2017-05-09T00:00:37Z
date available2017-05-09T00:00:37Z
date copyrightMay, 1999
date issued1999
identifier issn0892-7219
identifier otherJMOEEX-28132#131_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/122686
description abstractThis paper presents a method to determine the effective friction factor and overall heat transfer coefficient for a high-pressure, natural gas pipeline during fully transient flow conditions. Time-varying SCADA (supervisory control and data acquisition) measurements at the pipeline boundaries (i.e., inlet and outlet) provide boundary conditions for a transient flow model, as well as additional information which is utilized to determine these parameters. The resulting friction factor and overall heat transfer coefficient minimize the least-squared difference between the additional SCADA measurements at the pipeline outlet and the corresponding values predicted from the transient flow model. This concept is referred to as parameter estimation. The transient flow model is based on a numerical solution of the one-dimensional conservation equations (i.e., continuity, momentum, and energy) which are discretized using a highly accurate compact finite-difference scheme. The transient flow model and parameter estimation is incorporated into a computer program that is initially tested on a simple pipeline with steady flow conditions. The predicted outlet pressure and temperature using the estimated friction factor and overall heat transfer coefficient exactly matches the corresponding prescribed values. Subsequently, a portion of the Foothills Pipe Line Ltd. transmission system in Alberta is considered using time-varying SCADA flow measurements. The resulting outlet pressure and temperature from the transient flow model are in good agreement with SCADA measurements for this pipeline section.
publisherThe American Society of Mechanical Engineers (ASME)
titleEvaluating the Effective Friction Factor and Overall Heat Transfer Coefficient During Unsteady Pipeline Operation
typeJournal Paper
journal volume121
journal issue2
journal titleJournal of Offshore Mechanics and Arctic Engineering
identifier doi10.1115/1.2830078
journal fristpage131
journal lastpage136
identifier eissn1528-896X
keywordsFriction
keywordsPipelines
keywordsHeat transfer coefficients
keywordsFlow (Dynamics)
keywordsMeasurement
keywordsParameter estimation
keywordsTemperature
keywordsPressure
keywordsMomentum
keywordsBoundary-value problems
keywordsComputer software
keywordsEquations
keywordsFlow measurement
keywordsHigh pressure (Physics)
keywordsNatural gas distribution AND Data acquisition
treeJournal of Offshore Mechanics and Arctic Engineering:;1999:;volume( 121 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record