Show simple item record

contributor authorC. W. Haldeman
contributor authorM. G. Dunn
date accessioned2017-05-08T23:58:14Z
date available2017-05-08T23:58:14Z
date copyrightJanuary, 1998
date issued1998
identifier issn0889-504X
identifier otherJOTUEI-28664#1_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/121346
description abstractThis paper describes work done in preparation for the measurement of stage efficiency in a short-duration shock-tunnel facility. Efficiency measurements in this facility require knowledge of the flow with path pressure and temperature, rotating system moment of inertia, and mass flow. This paper describes in detail and improved temperature compensation technique for the pressure transducers (Kulite) to reduce thermal drift problems, and measurements of the rotating system moment of inertia. The temperature compensation has shown that the conversion to pressure is accurate to within 0.689 kPa (0.1 psi) over the 40°C test range. The measurement of the moment of inertia is shown to be accurate to within 0.7 percent of the average value.
publisherThe American Society of Mechanical Engineers (ASME)
titleHigh-Accuracy Turbine Performance Measurements in Short-Duration Facilities
typeJournal Paper
journal volume120
journal issue1
journal titleJournal of Turbomachinery
identifier doi10.1115/1.2841382
journal fristpage1
journal lastpage9
identifier eissn1528-8900
treeJournal of Turbomachinery:;1998:;volume( 120 ):;issue: 001
contenttypeFulltext