Show simple item record

contributor authorG. P. Xu
contributor authorK. W. Tou
contributor authorC. P. Tso
date accessioned2017-05-08T23:57:04Z
date available2017-05-08T23:57:04Z
date copyrightMarch, 1998
date issued1998
identifier issn0098-2202
identifier otherJFEGA4-27126#140_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/120687
description abstractVoid fraction and friction pressure drop measurements were made for an adiabatic, horizontal two-phase flow of air-water, air-oil across a horizontal in-line, 5 × 20 tube bundle with pitch-to-diameter ratio, P/D, of 1.28. For both air-water and air-oil flow, the experimental results showed that the average void fraction were less than the values predicted by a homogenous flow model, but were well correlated with the Martinelli parameter Xtt and liquid-only Froude number FrLO . The two-phase friction multiplier data exhibited an effect of flow pattern and mass velocity, and they could be well-correlated with the Martinelli parameter.
publisherThe American Society of Mechanical Engineers (ASME)
titleTwo-Phase Void Fraction and Pressure Drop in Horizontal Crossflow Across a Tube Bundle
typeJournal Paper
journal volume120
journal issue1
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.2819638
journal fristpage140
journal lastpage145
identifier eissn1528-901X
keywordsPorosity
keywordsPressure drop
keywordsFlow (Dynamics)
keywordsFriction
keywordsWater
keywordsMeasurement AND Two-phase flow
treeJournal of Fluids Engineering:;1998:;volume( 120 ):;issue: 001