description abstractThe goal of this study was to determine how vessel compliance (wall motion) and the phase angle between pressure and flow waves (impedance phase angle) affect the wall shear rate distribution in an atherogenic bifurcation geometry under sinusoidal flow conditions. Both rigid and elastic models replicating the human abdominal aortic bifurcation were fabricated and the wall shear rate distribution in the median plane of the bifurcation was determined using the photochromic flow visualization method. In the elastic model, three phase angle conditions were simulated (+12, −17, −61 deg), and the results compared with those obtained in a similar rigid model. The study indicates a very low (magnitude close to zero) and oscillatory wall shear rate zone within 1.5 cm distal to the curvature site on the outer (lateral) wall. In this low shear rate zone, unsteadiness (pulsatility) of the flow greatly reduces the mean (time-averaged) wall shear rate level. Vessel wall motion reduces the wall shear rate amplitude (time-varying component) up to 46 percent depending on the location and phase angle in the model. The mean wall shear rate is less influenced by the wall motion, but is reduced significantly in the low shear region (within 1.5 cm distal to the curvature site on the outer wall), thus rendering the wall shear rate waveform more oscillatory and making the site appear more atherogenic. The effect of the phase angle is most noteworthy on the inner wall close to the flow divider tip where the mean and amplitude of wall shear rate are 31 and 23 percent lower, respectively, at the phase angle of −17 deg than at −61 deg. However, the characteristics of the wall shear rate distribution in the low shear rate zone on the outer wall that are believed to influence localization of atherosclerotic disease, such as the mean wall shear rate level, oscillation in the wall shear rate waveform, and the length of the low and oscillatory wall shear rate zone, are similar for the three phase angles considered. The study also showed a large spatial variation of the phase angle between the wall shear stress waveform and the circumferential stress waveform (hoop stress due to radial artery expansion in response to pressure variations) near the bifurcation (up to 70 deg). The two stresses became more out of phase in the low mean shear rate zone on the outer wall (wall shear stress wave leading hoop stress wave as much as 125 deg at the pressure-flow phase angle of −61 deg) and were significantly influenced by the impedance phase angle.
publisherThe American Society of Mechanical Engineers (ASME)
titleWall Shear Rate Distribution in an Abdominal Aortic Bifurcation Model: Effects of Vessel Compliance and Phase Angle Between Pressure and Flow Waveforms
typeJournal Paper
journal volume119
journal issue3
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2796098
journal fristpage333
journal lastpage342
identifier eissn1528-8951
keywordsPressure
keywordsFlow (Dynamics)
keywordsShear (Mechanics)
keywordsBifurcation
keywordsVessels
keywordsStress
keywordsExterior walls
keywordsWaves
keywordsMotion
keywordsImpedance (Electricity)
keywordsFlow visualization
keywordsAtherosclerosis
keywordsOscillations
keywordsDiseases
keywordsGeometry AND Rendering
treeJournal of Biomechanical Engineering:;1997:;volume( 119 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record