Show simple item record

contributor authorM. E. Taslim
contributor authorD. M. Kercher
contributor authorT. Li
date accessioned2017-05-08T23:52:01Z
date available2017-05-08T23:52:01Z
date copyrightJanuary, 1996
date issued1996
identifier issn0889-504X
identifier otherJOTUEI-28648#20_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/117890
description abstractExperimental investigations have shown that the enhancement in heat transfer coefficients for air flow in a channel roughened with angled ribs is on the average higher than that roughened with 90 deg ribs of the same geometry. Secondary flows generated by the angled ribs are believed to be responsible for these higher heat transfer coefficients. These secondary flows also create a spanwise variation in heat transfer coefficient on the roughened wall with high levels of heat transfer coefficient at one end of the rib and low levels at the other end. In an effort basically to double the area of high heat transfer coefficients, the angled rib is broken at the center to form a V-shaped rib, and tests are conducted to investigate the resulting heat transfer coefficients and friction factors. Three different square rib geometries, corresponding to blockage ratios of 0.083, 0.125, and 0.167, with a fixed pitch-to-height ratio of 10, mounted on two opposite walls of a square channel in a staggered configuration, are tested in a stationary channel for 5000 < Re < 30,000. Heat transfer coefficients, friction factors, and thermal performances are compared with those of 90 deg, 45 deg, and discrete angled ribs. The V-shaped ribs are tested for both pointing upstream and downstream of the main flow. Test results show that: (a) 90 deg ribs represent the lowest thermal performance, based on the same pumping power, and is essentially the same for the 2:1 change in blockage ratio, (b) low-blockage-ratio (e/Dh = 0.083) V-shaped ribs pointing downstream produced the highest heat transfer enhancement and friction factors. Among all other geometries with blockage ratios of 0.125 and 0.167, 45 deg ribs showed the highest heat transfer enhancements with friction factors less than those of V-shaped ribs, (c) thermal performance of 45 deg ribs and the lowest blockage discrete ribs are among the highest of the geometries tested in this investigation, and (d) discrete angled ribs, although inferior to 45 deg and V-shaped ribs, produce much higher heat transfer coefficients and lower friction factors compared to 90 deg ribs.
publisherThe American Society of Mechanical Engineers (ASME)
titleDarryl E. Metzger Memorial Session Paper: Experimental Heat Transfer and Friction in Channels Roughened With Angled, V-Shaped, and Discrete Ribs on Two Opposite Walls
typeJournal Paper
journal volume118
journal issue1
journal titleJournal of Turbomachinery
identifier doi10.1115/1.2836602
journal fristpage20
journal lastpage28
identifier eissn1528-8900
keywordsFriction
keywordsHeat transfer
keywordsChannels (Hydraulic engineering)
keywordsHeat transfer coefficients
keywordsFlow (Dynamics)
keywordsAir flow AND Geometry
treeJournal of Turbomachinery:;1996:;volume( 118 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record