Show simple item record

contributor authorF. S. Henry
contributor authorP. E. Hughes
contributor authorT. V. How
contributor authorM. W. Collins
date accessioned2017-05-08T23:49:24Z
date available2017-05-08T23:49:24Z
date copyrightAugust, 1996
date issued1996
identifier issn0148-0731
identifier otherJBENDY-25965#302_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/116553
description abstractSteady flows in model proximal and distal end-to-side bypass anastomoses were simulated numerically. The predictions were compared to whole field measurements of the flow in in vitro models, and were shown to match well the general features of the measured flows. The predictions confirmed that the flows in end-to-side anastomoses are complex and three dimensional, and contain areas that could allow long residence times. Careful examination of the predictions revealed certain features of the flows not seen easily in the experiments. Shear stress and pressure on the vessel walls were predicted, and areas known to be prone to intimal hyperplasia were shown to correspond to areas of high spatial gradient of shear stress. Two anastomosis angles, 30 and 45 deg, were considered, and it was shown that the more acute angle may have some benefit in terms of the levels of shear gradients and the power required to drive the flow through the anastomosis.
publisherThe American Society of Mechanical Engineers (ASME)
titleNumerical Investigation of Steady Flow in Proximal and Distal End-to-Side Anastomoses
typeJournal Paper
journal volume118
journal issue3
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2796011
journal fristpage302
journal lastpage310
identifier eissn1528-8951
keywordsFlow (Dynamics)
keywordsShear (Mechanics)
keywordsGradients
keywordsStress
keywordsPressure
keywordsMeasurement AND Vessels
treeJournal of Biomechanical Engineering:;1996:;volume( 118 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record