Show simple item record

contributor authorG. J. W. King
contributor authorE. L. Damson
contributor authorC. B. Frank
contributor authorN. G. Shrive
date accessioned2017-05-08T23:46:41Z
date available2017-05-08T23:46:41Z
date copyrightFebruary, 1995
date issued1995
identifier issn0148-0731
identifier otherJBENDY-25949#41_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/115009
description abstractIn order to study the effect of intra-operative tensioning on the laxity and strength of healing ligament grafts in an animal model, a method of quantifying graft tension was needed. In this study a sensitive ligament tensioning device was developed to measure accurately the prefixation loads in the rabbit medial collateral ligament (MCL) graft. To verify that reproducible changes in ligament tension could be created with the tensioning device, a group of animals had their MCL grafts replaced at one of three different graft loads (tight, anatomic, or loose). The tensioning device consists of two posts which move relative to one another by means of an axial screw. The movable post, which is inserted into the tibial bone island of the MCL graft has a series of strain gauges which can measure the tension applied to the graft. The stationary post attaches to the tibial shaft, permitting the ligament graft to be tensioned relative to this fixed point. After graft tensioning and fixation, the animals were euthanized immediately postoperatively and their ligament load-deformation behavior was measured using an Instron materials testing machine. Specific measures of low load behavior was taken to quantify ligament laxity. Our results demonstrate that the tensioning device was capable of reproducibly altering prefixation graft load intra-operatively as well as MCL laxity immediately postoperatively. A baseline of laxity values was thus developed to follow changes in this laxity measure for future studies of MCL graft healing in this model.
publisherThe American Society of Mechanical Engineers (ASME)
titleA New Device and Method for Controlling the Load in Rabbit Medial Collateral Ligament Reconstructions
typeJournal Paper
journal volume117
journal issue1
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2792268
journal fristpage41
journal lastpage47
identifier eissn1528-8951
keywordsStress
keywordsTension
keywordsBone
keywordsStrain gages
keywordsDeformation
keywordsMachinery
keywordsScrews AND Materials testing
treeJournal of Biomechanical Engineering:;1995:;volume( 117 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record