description abstractRecent studies suggest that hip padding systems reduce the incidence of hip fractures during falls. However, no data exist on the force attenuating capacity of hip pads under realistic fall impact conditions, and thus it is difficult to compare the protective merit of various pad designs. Our goal is to design a comfortable hip padding system which reduces femoral impact force in a fall below the mean force required to fracture the elderly cadaveric femur. In pursuit of this objective, we designed and constructed a hip pad testing system consisting of an impact pendulum and surrogate human pelvis. We then developed a hip pad containing a shear-thickening material which allows for shunting of the impact energy away from the femur and into the surrounding soft tissue. Finally, we conducted experiments to assess whether the surrogate pelvis accurately represents the impact behavior of the human female pelvis in a fall, and to determine whether our energy-shunting pad attenuates femoral impact force in a fall more effectively than seven available padding systems. We found the surrogate pelvis accurately represented the human female pelvis in regional variation in soft tissue stiffness, total effective stiffness and damping, and impact force attenuation provided by trochanteric soft tissues. We also found that our padding system attenuated femoral impact force by 65 percent, thereby providing two times the force attenuation of the next best system. Moreover, the energy-shunting pad was the only system capable of lowering femoral impact force well below the mean force required to fracture the elderly femur in a fall loading configuration. These results suggest that the force attenuating potential of hip pads which focus on shunting energy away from the femur is superior to those which rely on absorbing energy in the pad material. While these in-vitro results are encouraging, carefully designed prospective clinical trials will be necessary to determine the efficacy of these approaches to hip fracture prevention.
publisherThe American Society of Mechanical Engineers (ASME)
titleEnergy-Shunting Hip Padding System Attenuates Femoral Impact Force in a Simulated Fall
typeJournal Paper
journal volume117
journal issue4
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2794200
journal fristpage409
journal lastpage413
identifier eissn1528-8951
keywordsForce
keywordsCushioning materials
keywordsSoft tissues
keywordsHip fractures
keywordsFracture (Process)
keywordsStiffness
keywordsTesting
keywordsPendulums
keywordsShear (Mechanics)
keywordsDamping AND Design