Show simple item record

contributor authorH. Weinans
contributor authorH. J. Grootenboer
contributor authorR. Huiskes
date accessioned2017-05-08T23:43:32Z
date available2017-05-08T23:43:32Z
date copyrightNovember, 1994
date issued1994
identifier issn0148-0731
identifier otherJBENDY-25945#393_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/113213
description abstractBone atrophy caused by stress-shielding may cause serious complications for the long-term fixation of hip stems. In particular, uncemented total hip arthroplasty is threatened by this problem, because the stems are usually larger and, as a consequence, stiffer than those of cemented implants. In the present study, the effects of fit and bonding characteristics of femoral hip stems were investigated, using the (nonlinear) finite element method in combination with adaptive bone remodeling theory to predict the bone density distribution in a bone or bone/implant configuration. Unknown parameters used in the theory, such as a reference equilibrium loading stimulus and a threshold (dead) zone of this stimulus, were established (triggered) by using the method to predict the density distributions in the natural femur and around fully coated uncemented implants. The computer simulation method can provide long term predictions of remodeling patterns around various implant configurations. Several cases were analyzed, whereby the coating conditions (fully, partly, or noncoated) and the fit characteristics (press fitted or overreamed) were varied. The computer predictions showed that partly coating can only significantly reduce bone atrophy relative to fully coated stems, when the coating is applied at a small region at the utmost proximal part of the stem. For smooth press-fit stems the predicted amount of bone loss (35 percent in the proximal medial region) was less than for a one-third proximally coated or a fully coated stem (50 to 54 percent predicted bone loss in the proximal medial region). The results showed that overreaming the femoral canal in the press fit case can have important effects. Distal overreaming gave reduced proximal atrophy. Proximal overreaming (or undersizing) resulted in a distal jam of the stem, a proximal “stress-bypass,” and dramatic proximal bone loss (up to 90 percent).
publisherThe American Society of Mechanical Engineers (ASME)
titleEffects of Fit and Bonding Characteristics of Femoral Stems on Adaptive Bone Remodeling
typeJournal Paper
journal volume116
journal issue4
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2895789
journal fristpage393
journal lastpage400
identifier eissn1528-8951
keywordsBonding
keywordsBone
keywordsPresses
keywordsCoating processes
keywordsCoatings
keywordsDensity
keywordsStress
keywordsEquilibrium (Physics)
keywordsFinite element methods
keywordsCanals
keywordsComputer simulation
keywordsArthroplasty AND Computers
treeJournal of Biomechanical Engineering:;1994:;volume( 116 ):;issue: 004
contenttypeFulltext