Show simple item record

contributor authorP. Kristal
contributor authorA. F. Tencer
contributor authorT. E. Trumble
contributor authorE. North
contributor authorD. Parvin
date accessioned2017-05-08T23:40:42Z
date available2017-05-08T23:40:42Z
date copyrightAugust, 1993
date issued1993
identifier issn0148-0731
identifier otherJBENDY-25919#218_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/111553
description abstractA new technique has been devised for measuring the in situ tension in small ligaments. It is based on measuring the tension in an axially loaded flexible cable with pinned endpoints by deflecting the cable laterally and measuring its lateral load and deformation. Studies were performed in which nylon line and bone ligament bone preparations were placed in a materials tester and loaded in axial tension. Axial load as measured by lateral load and deformation was found to agree with the known load to within 8 percent. The method was sensitive to error in determination of ligament length, nonperpendicularity of the laterally applied load to the long axis of the ligament, and when used in situ, impingement of the ligament on a third bone causing bending. A device, consisting of an LVDT mounted to a rigid frame with its core rod connected to a load cell, was developed. The position of the core rod was controlled by a manual screw drive, and a hook on the other end of the core rod was used to deflect the ligament laterally. This device was applied to the study of tensions in five ligaments of the palmar wrist carpus, in seven cadaver specimens. Results showed that the radioscaphocapitate (RSC) and radiolunate (RL) ligaments had significantly greater tensions than the lunotriquetral (LT), the triquetrocapitate (TC), and scaphocapitate (SC) ligaments. For the four positions of the hand tested, neutral, 14 deg radial and 14 deg ulnar deviation, and 28 deg of extension, ligament tensions were found to be unaffected by position. In all positions tested, all ligaments had measurable tension, demonstrating the importance of ligaments in maintaining the integrity of the wrist carpus.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Method for Measuring Tension in Small Ligaments: An Application to the Ligaments of the Wrist Carpus
typeJournal Paper
journal volume115
journal issue3
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2895478
journal fristpage218
journal lastpage224
identifier eissn1528-8951
keywordsTension
keywordsStress
keywordsBone
keywordsCables
keywordsDeformation
keywordsScrews
keywordsStructural frames
keywordsNylon fabrics AND Errors
treeJournal of Biomechanical Engineering:;1993:;volume( 115 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record