Show simple item record

contributor authorDavid A. Hoeltzel
contributor authorKurt Buzard
contributor authorKang-il Choe
contributor authorPeter Altman
date accessioned2017-05-08T23:37:46Z
date available2017-05-08T23:37:46Z
date copyrightMay, 1992
date issued1992
identifier issn0148-0731
identifier otherJBENDY-25884#202_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/109863
description abstractSpecimens of bovine, rabbit, and human corneas were systematically tested in uniaxial tension to experimentally determine their effective nonlinear stress-strain relations, and hysteresis. Cyclic tensile tests were performed over the physiologic load range of the cornea, up to a maximum of 10 percent strain beyond slack strain. Dimensional changes to corneal test specimens, due to varying laboratory environmental conditions, were also assessed. The measured stress-strain data was found to closely fit exponential power function relations typical of collagenous tissues when appropriate account was taken of specimen slack strain. These constitutive relations are very similar for rabbit, human and bovine corneas; there was no significant difference between the species after preconditioning by one cycle. The uniaxial stress strain curves for all species behave similarly in that their tangent moduli increase at high loads and decrease at low loads as a function of cycling. In the bovine and rabbit data, there is a general trend towards more elastic behavior from the first to second cycles, but there is little variation in these parameters from the second to third cycles. In comparison, the human data demonstrates relatively little change between cycles. Increases in width of corneal test specimens, up to a maximum of 2 percent were found to occur under 95 percent relative humidity test conditions over 10 minutes elapsed time test periods, while specimens which were exposed to normal laboratory conditions (45 percent RH) were found to shrink in width up to a maximum of 9.5 percent over the same elapsed time period. The thickness of the test specimens were observed to decrease by 3 percent in 95 percent relative humidity and by 12 percent in 45 percent relative humidity over the same elapsed time period.
publisherThe American Society of Mechanical Engineers (ASME)
titleStrip Extensiometry for Comparison of the Mechanical Response of Bovine, Rabbit, and Human Corneas
typeJournal Paper
journal volume114
journal issue2
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2891373
journal fristpage202
journal lastpage215
identifier eissn1528-8951
keywordsStrips
keywordsCornea
keywordsCycles
keywordsStress
keywordsStress-strain curves
keywordsBiological tissues
keywordsConstitutive equations
keywordsStress-strain relations
keywordsTension
keywordsThickness
keywordsPhysiology AND Elasticity
treeJournal of Biomechanical Engineering:;1992:;volume( 114 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record