Show simple item record

contributor authorJ. A. Hill
contributor authorP. Hanley
contributor authorK. Ohland
contributor authorS. Kirstukas
contributor authorJ. L. Lewis
contributor authorW. D. Lew
contributor authorR. E. Hunter
date accessioned2017-05-08T23:29:25Z
date available2017-05-08T23:29:25Z
date copyrightMay, 1989
date issued1989
identifier issn0148-0731
identifier otherJBENDY-25847#97_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/105073
description abstractThe goal of this in vitro study was to investigate the initial postoperative mechanical state of the knee with various types of anterior cruciate ligament (ACL) reconstructions. An experimental knee testing system was developed for the in vitro measurement of ligament forces and three-dimensional joint motion as external loads were applied to fresh knee specimens. Two groups of knee specimens were tested. In test series #1, two intraarticular reconstructions were performed in each of five specimens using semifree and free patellar tendon grafts with bone blocks. In test series #2, a more carefully controlled intraarticular reconstruction was performed in five specimens using a semifree composite graft consisting of the semitendinosus and gracilis tendons augmented with the Ligament Augmentation Device. Ligament force and joint motion data were collected as anteriorly directed tibial loads were applied to the normal joint, the joint with a cut ACL and the reconstructed joint. These knee joint states were compared on the basis of ACL or graft forces, joint motion and load sharing by the collateral ligaments. The dominate result of the study was that the forces and motions defining the mechanical state of the knee after the ACL reconstructions in both test series were highly variable and abnormal when compared to the normal knee state. The higher level of surgical control series #2 did not decrease this variability. There was a poor correlation between motion of the reconstructed knee relative to normal, and the ACL graft force. There was little consistent difference in force and motion results between the surgical procedures tested.
publisherThe American Society of Mechanical Engineers (ASME)
titleKnee Joint Motion and Ligament Forces Before and After ACL Reconstruction
typeJournal Paper
journal volume111
journal issue2
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.3168361
journal fristpage97
journal lastpage106
identifier eissn1528-8951
keywordsForce
keywordsMotion
keywordsAnterior cruciate ligament
keywordsKnee
keywordsStress
keywordsSurgery
keywordsTendons
keywordsTesting
keywordsBone AND Composite materials
treeJournal of Biomechanical Engineering:;1989:;volume( 111 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record