Shear Performance of Fire-Damaged Reinforced Concrete Beams Repaired by a Bolted Side-Plating Technique
Publisher: American Society of Civil Engineers
Residual Seismic Performance of Fire-Damaged Reinforced Concrete Frame Structure with Metallic Yielding Dampers
Publisher: ASCE
Abstract: Structures with varying dampers have been widely designed and constructed for earthquake resistance. However, the residual seismic performance of these damped structures could not be guaranteed after being exposed to a ...
Mechanical Properties of Engineered Cementitious Composites Subjected to Elevated Temperatures
Publisher: American Society of Civil Engineers
Abstract: This paper presents the results of an extensive test program on the residual mechanical properties of engineered cementitious composites (ECC) exposed to elevated temperatures up to 800°C. ECC cube specimens were heated ...
Direct Tensile Properties and Stress–Strain Model of UHP-ECC
Publisher: ASCE