Air-Handling-Unit Discharge Air Temperature Reset Based on Outdoor Air Temperature and Cooling Energy Performance in an Office Building
Publisher: ASCE
Abstract: In many office buildings, an air-handling unit (AHU) in a variable air volume (VAV) system is operated using discharge air temperature (DAT) simply fixed at a particular set point. However, this simply fixed control causes ...
Strategic Planning for Drought Mitigation under Climate Change
Publisher: American Society of Civil Engineers
Abstract: Droughts continue to be a major natural hazard, and mounting evidence of global warming confronts society with a pressing question: Will climate change aggravate the risk of drought at the local scale? Are current ...