YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    Search 
    •   YE&T Library
    • Search
    •   YE&T Library
    • Search
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Search

    Show Advanced FiltersHide Advanced Filters

    Filters

    Use filters to refine the search results.

    Now showing items 1-10 of 14

    • Relevance
    • Title Asc
    • Title Desc
    • Year Asc
    • Year Desc
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100
  • Export
    • CSV
    • RIS
    • Sort Options:
    • Relevance
    • Title Asc
    • Title Desc
    • Issue Date Asc
    • Issue Date Desc
    • Results Per Page:
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100

    Design and Performance Evaluation of a Heat Exchanger Network for a Cogeneration DMS to Various Thermal Utilization Applications 

    Source: Journal of Nuclear Engineering and Radiation Science:;2016:;volume( 002 ):;issue: 004:;page 41006
    Author(s): Ge, Gaoming; Simonson, Carey J.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Hitachi-GE developed a 300-MWe-class modular simplified and medium small reactor (DMS) between 2000 and 2004. It was designed to have merits over traditional nuclear power plants in areas of lower initial capital investment, ...
    Request PDF

    A New Approach to Delay or Prevent Frost Formation in Membranes 

    Source: Journal of Heat Transfer:;2019:;volume( 141 ):;issue: 001:;page 11503
    Author(s): Navid, Pooya; Niroomand, Shirin; Simonson, Carey J.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Saturation of the water vapor is essential to form frost inside a permeable membrane. The main goal of this paper is to develop a numerical model that can predict temperature and humidity inside a membrane in order to show ...
    Request PDF

    Performance Improvement of Membrane Energy Exchanger Using Ultrasound for Heating, Ventilation, and Air Conditioning Application 

    Source: Journal of Thermal Science and Engineering Applications:;2021:;volume( 014 ):;issue: 005:;page 51015-1
    Author(s): Gurubalan, A.; Maiya, M. P.; Geoghegan, Patrick; Simonson, Carey J.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Air conditioning (AC) systems consume the maximum proportion of the total electricity used in the building sector. The demand for AC systems is expected to increase exponentially in the coming years due to various reasons ...
    Request PDF

    Thermo-Economic Performance of a Cogeneration Medium–Small Modular Nuclear Reactor Plant in Canada 

    Source: Journal of Nuclear Engineering and Radiation Science:;2017:;volume( 003 ):;issue: 003:;page 31002
    Author(s): Ge, Gaoming; Ikegawa, Tomohiko; Nishida, Koji; Simonson, Carey J.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Hitachi-GE developed a 300 MWel class modular simplified and medium small reactor (DMS) concept, and the DMS was originally designed for generating electricity only. In this study, the feasibility of a cogeneration DMS ...
    Request PDF

    Experimental Pressure Drop and Heat Transfer in a Rectangular Channel With a Sinusoidal Porous Screen 

    Source: Journal of Heat Transfer:;2015:;volume( 137 ):;issue: 004:;page 42601
    Author(s): Mahmood, Gazi I.; Simonson, Carey J.; Besant, Robert W.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Experiments are conducted to investigate turbulence enhancing effects of a porous meshscreen with a sinusoidal shape normal to the flow direction inside a rectangular cross section air channel at low Reynolds numbers (i.e., ...
    Request PDF

    Extension of the Concepts of Heat Capacity Rate Ratio and Effectiveness Number of Transfer Units Model to the Coupled Heat and Moisture Exchange in Liquid to Air Membrane Energy Exchangers 

    Source: Journal of Heat Transfer:;2016:;volume( 138 ):;issue: 009:;page 92001
    Author(s): Kamali, Houman; Ge, Gaoming; Besant, Robert W.; Simonson, Carey J.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The underlying concept of the standard effectivenessnumber of transfer units (NTU) model is that the effectiveness of an exchanger can be correlated to two dimensionless parameters, namely, heat capacity ratio (Cr) and ...
    Request PDF

    Effects of Physical and Sorption Properties of Desiccant Coating on Performance of Energy Wheels 

    Source: Journal of Heat Transfer:;2017:;volume( 139 ):;issue: 006:;page 62601
    Author(s): Fathieh, Farhad; Nezakat, Majid; Evitts, Richard W.; Simonson, Carey J.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Desiccant-coated energy wheels are rotary-air-to-air energy exchangers widely used in ventilation systems to reduce the energy consumption required in industrial environments and commercial buildings. In this study, the ...
    Request PDF

    Effects of Physical and Sorption Properties of Desiccant Coating on Performance of Energy Wheels 

    Source: Journal of Heat Transfer:;2017:;volume( 139 ):;issue: 006:;page 62601
    Author(s): Fathieh, Farhad; Nezakat, Majid; Evitts, Richard W.; Simonson, Carey J.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Desiccant-coated energy wheels are rotary-air-to-air energy exchangers widely used in ventilation systems to reduce the energy consumption required in industrial environments and commercial buildings. In this study, the ...
    Request PDF

    Transient Operation of Sensible Fixed-Bed Regenerators 

    Source: Journal of Thermal Science and Engineering Applications:;2022:;volume( 014 ):;issue: 008:;page 81016-1
    Author(s): Ramin, Hadi; Krishnan, Easwaran N.; Gurubalan, Annadurai; Simonson, Carey J.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Fixed-bed regenerator is a type of air-to-air energy exchanger and recently introduced for energy recovery application in heating, ventilation, and air conditioning (HVAC) systems because of their high heat transfer ...
    Request PDF

    A Field Study of a Low Flow Internally Cooled/Heated Liquid Desiccant Air Conditioning System: Quasi Steady and Transient Performance 

    Source: Journal of Solar Energy Engineering:;2016:;volume( 138 ):;issue: 003:;page 31009
    Author(s): Abdel; McNevin, Chris; Crofoot, Lisa; Harrison, Stephen J.; Simonson, Carey J.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The field performance of a lowflow internally cooled/heated liquid desiccant air conditioning (LDAC) system is investigated in this paper. The quasisteady performance (sensible and latent heat transfer rates, coefficient ...
    Request PDF
    • 1
    • 2
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     

    Author

    ... View More

    Publisher

    Year

    Type

    Content Type

    Publication Title

    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian