A Generalized Constraint Model for Two-Dimensional Beam Flexures: Nonlinear Load-Displacement Formulation
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: To utilize beam flexures in constraint-based flexure mechanism design, it is important to develop qualitative and quantitative understanding of their constraint characteristics in terms of stiffness ...
A Generalized Constraint Model for Two-Dimensional Beam Flexures: Nonlinear Strain Energy Formulation
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The beam constraint model (BCM), presented previously, captures pertinent nonlinearities to predict the constraint characteristics of a generalized beam flexure in terms of its stiffness and error ...
Constraint-Based Design of Parallel Kinematic XY Flexure Mechanisms
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: This paper presents parallel kinematic XY flexure mechanism designs based on systematic constraint patterns that allow large ranges of motion without causing over-constraint or significant error ...
Elastic Averaging in Flexure Mechanisms: A Three-Beam Parallelogram Flexure Case Study
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Redundant constraints are generally avoided in mechanism design because they can lead to binding or loss in expected mobility. However, in certain distributed-compliance flexure mechanism geometries, ...
Characteristics of Beam-Based Flexure Modules
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The beam flexure is an important constraint element in flexure mechanism design. Nonlinearities arising from the force equilibrium conditions in a beam significantly affect its properties as a ...
Electromagnetic Coupling in a dc Motor and Tachometer Assembly
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: This paper presents an enhanced tachometer model that takes into account the effect of electromagnetic coupling that can exist between the actuator and sensor in an integrated dc motor-tachometer ...
FlexDex™ : A Minimally Invasive Surgical Tool With Enhanced Dexterity and Intuitive Control
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: This paper presents a new minimally invasive surgical (MIS) tool design paradigm that enables enhanced dexterity, intuitive control, and natural force feedback in a low-cost compact package. The ...