YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    Search 
    •   YE&T Library
    • Search
    •   YE&T Library
    • Search
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Search

    Show Advanced FiltersHide Advanced Filters

    Filters

    Use filters to refine the search results.

    Now showing items 1-10 of 10

    • Relevance
    • Title Asc
    • Title Desc
    • Year Asc
    • Year Desc
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100
  • Export
    • CSV
    • RIS
    • Sort Options:
    • Relevance
    • Title Asc
    • Title Desc
    • Issue Date Asc
    • Issue Date Desc
    • Results Per Page:
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100

    Chip Level Thermal Performance Measurements in Two-Phase Immersion Cooling 

    Source: Journal of Electronic Packaging:;2023:;volume( 145 ):;issue: 004:;page 41101-1
    Author(s): Shah, Jimil M.; Crandall, Thomas; Tuma, Phillip E.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Two-phase immersion cooling (2PIC) has been proposed as a means of economically increasing overall energy efficiency while accommodating increased chip powers and system-level power density. Designers unfamiliar with ...
    Request PDF

    Identification and Characterization of Particulate Contaminants Found at a Data Center Using Airside Economization 

    Source: Journal of Electronic Packaging:;2019:;volume( 141 ):;issue: 003:;page 31003
    Author(s): Shah, Jimil M.; Misrak, Abel; Agonafer, Dereje; Kaler, Mike
    Publisher: American Society of Mechanical Engineers (ASME)
    Abstract: Contamination due to the use of airside economizer has become a major issue that cost companies revenue. This issue will continue to rise as server components become smaller, densely packed, and as companies move into more ...
    Request PDF

    Experimental Description of Information Technology Equipment Reliability Exposed to a Data Center Using Airside Economizer Operating in Recommended and Allowable ASHRAE Envelopes in an ANSI/ISA Classified G2 Environment 

    Source: Journal of Electronic Packaging:;2020:;volume( 142 ):;issue: 002
    Author(s): Awe, Oluwaseun; Shah, Jimil M.; Agonafer, Dereje; Singh, Prabjit; Kannan, Naveen; Kaler, Mike
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Airside economizers lower the operating cost of data centers by reducing or eliminating mechanical cooling. It, however, increases the risk of reliability degradation of information technology (IT) equipment due to ...
    Request PDF

    Simplified and Detailed Analysis of Data Center Particulate Contamination at Server and Room Level Using Computational Fluid Dynamics 

    Source: Journal of Electronic Packaging:;2022:;volume( 144 ):;issue: 002:;page 24501-1
    Author(s): Saini, Satyam; Shahi, Pardeep; Bansode, Pratik; Shah, Jimil M.; Agonafer, Dereje
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Continuous rise in cloud computing and other web-based services propelled the data center proliferation seen over the past decade. Traditional data centers use vapor-compression-based cooling units that not only reduce ...
    Request PDF

    Measurement of the Thermal Performance of a Custom-Build Single-Phase Immersion Cooled Server at Various High and Low Temperatures for Prolonged Time 

    Source: Journal of Electronic Packaging:;2020:;volume( 142 ):;issue: 001:;page 011010-1
    Author(s): Bansode, Pratik V.; Shah, Jimil M.; Gupta, Gautam; Agonafer, Dereje; Patel, Harsh; Roe, David; Tufty, Rick
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The next radical change in the thermal management of data centers is to shift from conventional cooling methods like air-cooling to direct liquid cooling to enable high thermal mass and corresponding superior cooling. There ...
    Request PDF

    Development of a Precise and Cost-Effective Technique to Measure Deliquescent Relative Humidity of Particulate Contaminants and Determination of the Operating Relative Humidity of a Data Center Utilizing Airside Economization 

    Source: Journal of Electronic Packaging:;2020:;volume( 142 ):;issue: 004:;page 041103-1
    Author(s): Shah, Jimil M.; Anand, Roshan; Singh, Prabjit; Saini, Satyam; Cyriac, Rawhan; Agonafer, Dereje; Kaler, Mike
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A remarkable amount of energy in data centers is consumed in eliminating the heat generated by the information technology (IT) equipment to maintain and ensure safe operating conditions and optimum performance. The ...
    Request PDF

    Evaluating the Reliability of Passive Server Components for Single-Phase Immersion Cooling 

    Source: Journal of Electronic Packaging:;2021:;volume( 144 ):;issue: 002:;page 21109-1
    Author(s): Shah, Jimil M.; Padmanaban, Keerthivasan; Singh, Hrishabh; Duraisamy Asokan, Surya; Saini, Satyam; Agonafer, Dereje
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The adoption of single-phase liquid immersion cooling (Sp-LIC) for Information Technology equipment provides an excellent cooling platform coupled with significant energy savings. There are, however, very limited studies ...
    Request PDF

    Qualitative Study of Cumulative Corrosion Damage of Information Technology Equipment in a Data Center Utilizing Air-Side Economizer Operating in Recommended and Expanded ASHRAE Envelope 

    Source: Journal of Electronic Packaging:;2017:;volume( 139 ):;issue: 002:;page 20903
    Author(s): Shah, Jimil M.; Awe, Oluwaseun; Gebrehiwot, Betsegaw; Agonafer, Dereje; Singh, Prabjit; Kannan, Naveen; Kaler, Mike
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Deployment of airside economizers (ASEs) in data centers is rapidly gaining acceptance to reduce cost of cooling energy by reducing hours of operation of computer room air conditioning (CRAC) units. Airside economization ...
    Request PDF

    Reliability Considerations for Oil Immersion-Cooled Data Centers 

    Source: Journal of Electronic Packaging:;2019:;volume( 141 ):;issue: 002:;page 21007
    Author(s): Shah, Jimil M.; Eiland, Richard; Rajmane, Pavan; Siddarth, Ashwin; Agonafer, Dereje; Mulay, Veerendra
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The improved efficiency of mineral oil may offer simplicity in facility design compared to traditional air cooling and provide a means for cost savings. Despite its improved cooling efficiency and cost savings, a mineral ...
    Request PDF

    Reliability Considerations for Oil Immersion-Cooled Data Centers 

    Source: Journal of Electronic Packaging:;2019:;volume( 141 ):;issue: 002:;page 21007
    Author(s): Shah, Jimil M.; Eiland, Richard; Rajmane, Pavan; Siddarth, Ashwin; Agonafer, Dereje; Mulay, Veerendra
    Publisher: American Society of Mechanical Engineers (ASME)
    Abstract: The improved efficiency of mineral oil may offer simplicity in facility design compared to traditional air cooling and provide a means for cost savings. Despite its improved cooling efficiency and cost savings, a mineral ...
    Request PDF
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     

    Author

    ... View More

    Publisher

    Year

    Type

    Content Type

    Publication Title

    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian