Assessing Corrosion Damage in Posttensioned Concrete Structures Using Acoustic Emission
Publisher: American Society of Civil Engineers
Early Corrosion Detection in Prestressed Concrete Girders Using Acoustic Emission
Publisher: American Society of Civil Engineers
Abstract: Long-term corrosion tests were performed on prestressed T-girders measuring 4.98 m (16 ft, 4 in.). The test program was composed of four specimens, including one control. The specimens were subjected to wet/dry cycles using ...
On-Site Acoustic-Emission Monitoring for Assessment of a Prestressed Concrete Double-Tee-Beam Bridge without Plans
Publisher: American Society of Civil Engineers
Abstract: Acoustic emission was used in this study to assess the condition of a simple-span, prestressed concrete bridge located in southern New Mexico during a proof test. The 40-year-old bridge is county owned and no design plans ...