YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    Search 
    •   YE&T Library
    • Search
    •   YE&T Library
    • Search
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Search

    Show Advanced FiltersHide Advanced Filters

    Filters

    Use filters to refine the search results.

    Now showing items 1-8 of 8

    • Relevance
    • Title Asc
    • Title Desc
    • Year Asc
    • Year Desc
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100
  • Export
    • CSV
    • RIS
    • Sort Options:
    • Relevance
    • Title Asc
    • Title Desc
    • Issue Date Asc
    • Issue Date Desc
    • Results Per Page:
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100

    The Effect of Stent Design on the Restenosis Rate 

    Source: Journal of Medical Devices:;2008:;volume( 002 ):;issue: 002:;page 27526
    Author(s): Aswini K. Muttyam; Linxia Gu
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Within 6months from the initial procedure, restenosis is observed in 40% of the cases treated with coronary stenting. Exact reasons for restenosis are yet to be explored. Stenting is a mechanical ...
    Request PDF

    On the Importance of Modeling Stent Procedure for Predicting Arterial Mechanics 

    Source: Journal of Biomechanical Engineering:;2012:;volume( 134 ):;issue: 012:;page 121005
    Author(s): Shijia Zhao; Linxia Gu; Stacey R. Froemming
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The stent-artery interactions have been increasingly studied using the finite element method for better understanding of the biomechanical environment changes on the artery and its implications. ...
    Request PDF

    Performance of Self-Expanding Nitinol Stent in a Curved Artery: Impact of Stent Length and Deployment Orientation 

    Source: Journal of Biomechanical Engineering:;2012:;volume( 134 ):;issue: 007:;page 71007
    Author(s): Shijia Zhao; Linxia Gu; Stacey R. Froemming
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The primary aim of this work was to investigate the performance of self-expanding Nitinol stents in a curved artery through finite element analysis. The interaction between a PROTÉGÉTM ...
    Request PDF

    Finite Element Analysis of the Implantation of a Self-Expanding Stent: Impact of Lesion Calcification 

    Source: Journal of Medical Devices:;2012:;volume( 006 ):;issue: 002:;page 21001
    Author(s): Shijia Zhao; Linxia Gu; Stacey R. Froemming
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: In this work, the deployment of a self-expanding stent in a stenosed artery was evaluated through finite element analysis. The three-layered structure of the artery and their material properties ...
    Request PDF

    The Impact of Wire Stent Fabrication Technique on the Performance of Stent Placement 

    Source: Journal of Medical Devices:;2012:;volume( 006 ):;issue: 001:;page 11007
    Author(s): Shijia Zhao; Xiangyi (Cheryl) Liu; Linxia Gu
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Braided wire stents demonstrate distinct characteristics compared to welded ones. In this study, both braided and welded wire stents with the same nominal dimensions were crimped inside a sheath ...
    Request PDF

    Finite Element Analysis Using Nonconforming Mesh 

    Source: Journal of Computing and Information Science in Engineering:;2008:;volume( 008 ):;issue: 003:;page 31005
    Author(s): Ashok V. Kumar; Sanjeev Padmanabhan; Linxia Gu; Ravi Burla
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A method for finite element analysis using a regular or structured grid is described that eliminates the need for generating conforming mesh for the geometry. The geometry of the domain is ...
    Request PDF

    Case Study of Quantifying Energy Loss through Ceiling-Attic Recessed Lighting Fixtures through 3D Numerical Simulation 

    Source: Journal of Architectural Engineering:;2017:;Volume ( 023 ):;issue: 001
    Author(s): Ri Na; Shengmao Lin; Zhigang Shen; Linxia Gu
    Publisher: American Society of Civil Engineers
    Abstract: Air leakage through recessed lighting fixtures has been identified as a common issue that causes extra energy consumption in residential buildings. However, few quantitative studies in this area were found. As such, a ...
    Request PDF

    The Relation Between the Arterial Stress and Restenosis Rate After Coronary Stenting 

    Source: Journal of Medical Devices:;2010:;volume( 004 ):;issue: 003:;page 31005
    Author(s): Linxia Gu; Aswini K. Muttyam; James M. Hammel; Shijia Zhao
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Two commercially available stents (the Palmaz–Schatz (PS) and S670 stents) with reported high and low restenosis rates, respectively, have been investigated in this paper. Finite element models ...
    Request PDF
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     

    Author

    ... View More

    Publisher

    Year

    Type

    Content Type

    Publication Title

    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian