An In Vitro Comparative Study of St. Jude Medical and Edwards-Duromedics Bileaflet Valves Using Laser Anemometry
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: An in vitro comparative study of St. Jude (SJ) and Edwards-Duromedics (DM) Bileaflet valves was performed under steady and physiological pulsatile flow conditions in an axisymmetric chamber using ...
A Note on the Blood Analog for In-Vitro Testing of Heart Valve Bioprostheses
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Glycerol solution with the viscosity coefficient similar to that of blood is used in evaluating the performance characteristics of prosthetic heart valves in the laboratory. However, physiological ...
Dynamic Behavior Analysis of Mechanical Monoleaflet Heart Valve Prostheses in the Opening Phase
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: In this paper, fluttering behavior of a mechanical monoleaflet tilting disk heart valve prostheses during the opening phase was analyzed. The impact between the occluder and the guiding strut ...
Transient Behavior Analysis of a Mechanical Monoleaflet Heart Valve Prosthesis in the Closing Phase
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: In this paper, an analysis of the dynamics in the closing phase of the occluder of a mechanical monoleaflet heart valve prosthesis is presented. The dynamic analysis of the fluid in the ...
Erratum: “An Experimental Study of Package Cushioning for the Human Head” (Journal of Applied Mechanics, 1976, 43, p. 469)
Publisher: The American Society of Mechanical Engineers (ASME)
An Experimental Study of Package Cushioning for the Human Head
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: An experiment was performed to determine the container acceleration and pressure distribution in a Plexiglass cylinder, filled either with water or 3 percent set-gelatin, and impacted against a ...
Package Cushioning for the Human Head—1: Analytical Considerations
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The closed head impact problem was idealized as a fluid-filled cylinder attached to a spring-dashpot element striking a rigid wall. The rigid cylinder represents the skull, the fluid denotes ...
Numerical Simulation of Steady Flow in a Two-Dimensional Total Artificial Heart Model
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: In this paper, a numerical simulation of steady laminar and turbulent flow in a twodimensional model for the total artificial heart is presented. A trileaflet polyurethane valve was simulated ...
Cavitation Dynamics of Medtronic Hall Mechanical Heart Valve Prosthesis: Fluid Squeezing Effect
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The cause of cavitation in mechanical heart valves is investigated with Medtronic Hall tilting disk valves in an in vitro flow system simulating the closing event in the mitral position. ...
The Exact Solution of the Translational Acceleration of a Low Modulus Elastic Medium in Rigid Spherical Shells—Implications for Head Injury Models
Publisher: The American Society of Mechanical Engineers (ASME)