Search
Now showing items 1-8 of 8
Estimation of Organ Transport Function: Model-Free Deconvolution by Recursive Quadratic Programming Optimization
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: A model-free deconvolution method is proposed for evaluating the frequency distribution function of organ transit times. The deconvolution is treated as a nonlinear constrained optimization problem ...
Numerical Investigation of Coil Configurations That Provide Ultrahigh Packing Density of Saccular Aneurysms
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The long-term outcome of endovascular coiling of cerebral aneurysms is directly related to the packing density at the time of treatment. In general, the highest packing density achievable is ...
Steady Inspiratory Flow in a Model Symmetric Bifurcation
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Flow in a bifurcating tube system typifying a major bronchial bifurcation is studied experimentally with a two color, two velocity component laser Doppler anemometer. The flow loop is composed ...
Steady Expiratory Flow in a Model Symmetric Bifurcation
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: A model symmetric bifurcation was employed to simulate steady expiratory flow in the upper part of the human central airways. A two color, two component laser Doppler anemometer was used to ...
Comparison of the In Vitro Hemodynamic Performance of New Flow Diverters for Bypass of Brain Aneurysms
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: One possible treatment for cerebral aneurysms is a porous tubular structure, similar to a stent, called a flow diverter. A flow diverter can be placed across the neck of a cerebral aneurysm ...
In Vitro Evaluation of Flow Divertors in an Elastase-Induced Saccular Aneurysm Model in Rabbit
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Endovascular coiling is an acceptable treatment of intracranial aneurysms, yet long term follow-ups suggest that endovascular coiling fails to achieve complete aneurysm occlusions particularly in ...
Correlation Between Angiographic and Particle Image Velocimetry Quantifications of Flow Diverters in an In Vitro Model of Elastase-Induced Rabbit Aneurysms
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The rupture of a cerebral aneurysm can result in a hemorrhagic stroke. A flow diverter, which is a porous tubular mesh, can be placed across the neck of a cerebral aneurysm to induce the ...
Modeling the Interaction of Coils With the Local Blood Flow After Coil Embolization of Intracranial Aneurysms
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Aneurysmal recanalization and coil compaction after coil embolization of intracranial aneurysms are seen in as many as 40% of cases. Higher packing density has been suggested to reduce both ...
CSV
RIS