Search
Now showing items 1-8 of 8
A Two-Pressure Humidity Generator
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: A device for precisely humidifying a process gas is presented, with particular application to document preservation. The machine is designed to minimize the risk of damage from overpressure by ...
Design of Novel Catheter Insertion Device
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Poor positioning of needles and catheters may result in repeated attempts at correct placement, injury to adjacent structures or infusions into inappropriate spaces. Existing catheter insertion ...
Sustainable Design?
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The Brundtland Commission defined sustainable development as the development that meets the needs of the present without compromising the ability of future generations to meet their own needs. ...
A Device for Harvesting Energy From Rotational Vibrations
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: A new device designed to harvest rotational vibration energy is presented. The device is modeled as a spring-mass-damper system connected to a vibration source where a torsion rod is used as ...
Ankle Rehabilitation via Compliant Mechanisms
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: A flexure-based ankle rehabilitation device utilizes the linear elastic force-deflection characteristics of certain types of flexure beams to measure the forces and torques output by the human ...
Design of a Pressure Measuring Syringe
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Endotracheal intubations are performed on thousands of patients each day. Intubation is achieved by inserting a small plastic tube down a patient’s trachea, allowing oxygen and anesthetics to ...
An Implantable Port for Office Laparoscopy: The AbView Access Port
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Due to the tendency of ovarian cancer to spread in small sections throughout the abdominal cavity, it is presently difficult to detect early stage cancer recurrence following the primary ...
Design of a Pressure-Sensing Laparoscopic Grasper
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: In order to improve dexterity and tactile feedback during grasping in laparoscopic surgery, a pressure-sensing, ergonomic laparoscopic grasper with parallel motion grasper jaws has been designed, ...