| description abstract | A method for increasing the peak output of steam power plants through use of a low-pressure feedwater storage system is presented. The generalized availability analysis involves only the low-pressure turbine, low-pressure feedwater heaters, and the storage system. With daily cycling and storage charging at near base load conditions, the turnaround efficiency of the energy storage system was found to approach 100 percent. Storage system turnaround efficiency is decreased when the energy is stored during plant part-load operation. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Energy Storage Using Low-Pressure Feedwater | |
| type | Journal Paper | |
| journal volume | 107 | |
| journal issue | 3 | |
| journal title | Journal of Engineering for Gas Turbines and Power | |
| identifier doi | 10.1115/1.3239774 | |
| journal fristpage | 569 | |
| journal lastpage | 573 | |
| identifier eissn | 0742-4795 | |
| keywords | Feedwater | |
| keywords | Energy storage | |
| keywords | Pressure | |
| keywords | Storage | |
| keywords | Stress | |
| keywords | Turbines | |
| keywords | Industrial plants AND Thermal power stations | |
| tree | Journal of Engineering for Gas Turbines and Power:;1985:;volume( 107 ):;issue: 003 | |
| contenttype | Fulltext | |