Hydrogen Damage in a 1250-Psi BoilerSource: Journal of Engineering for Gas Turbines and Power:;1964:;volume( 086 ):;issue: 003::page 341Author:E. E. Galloway
DOI: 10.1115/1.3677599Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: This paper covers the case history of hydrogen damage in a relatively low-pressure boiler (1250 psi). Two failures are discussed, as well as the pertinent facts concerning boiler operation, chemical treatment, and cleaning.
keyword(s): Boilers , Hydrogen , Pressure AND Failure ,
|
Show full item record
| contributor author | E. E. Galloway | |
| date accessioned | 2017-05-08T23:19:50Z | |
| date available | 2017-05-08T23:19:50Z | |
| date copyright | July, 1964 | |
| date issued | 1964 | |
| identifier issn | 1528-8919 | |
| identifier other | JETPEZ-26635#341_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/99624 | |
| description abstract | This paper covers the case history of hydrogen damage in a relatively low-pressure boiler (1250 psi). Two failures are discussed, as well as the pertinent facts concerning boiler operation, chemical treatment, and cleaning. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Hydrogen Damage in a 1250-Psi Boiler | |
| type | Journal Paper | |
| journal volume | 86 | |
| journal issue | 3 | |
| journal title | Journal of Engineering for Gas Turbines and Power | |
| identifier doi | 10.1115/1.3677599 | |
| journal fristpage | 341 | |
| journal lastpage | 343 | |
| identifier eissn | 0742-4795 | |
| keywords | Boilers | |
| keywords | Hydrogen | |
| keywords | Pressure AND Failure | |
| tree | Journal of Engineering for Gas Turbines and Power:;1964:;volume( 086 ):;issue: 003 | |
| contenttype | Fulltext |