Show simple item record

contributor authorD. C. Winter
contributor authorR. L. Pimmel
contributor authorB. F. Lewis
date accessioned2017-05-08T23:12:46Z
date available2017-05-08T23:12:46Z
date copyrightNovember, 1982
date issued1982
identifier issn0148-0731
identifier otherJBENDY-25726#311_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/95517
description abstractThe specific compliance of the tracheas of seven anesthetized dogs were measured in vivo under control conditions and with the cervical vagi cut and then stimulated. Specific compliances ranged from 7.9 to 12.2 × 10−6 (dynes/cm2 )−1 for the control measurements and were not significantly different after vagotomy. Stimulation of the vagi reduced the compliance of the trachea by 40–70 percent. These results agree with other reported in-vivo results but the specific compliance values are noticeably less than the values reported for excised trachea.
publisherThe American Society of Mechanical Engineers (ASME)
titleDirect In-Vivo Measurements of the Elastic Properties of Canine Trachea
typeJournal Paper
journal volume104
journal issue4
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.3138364
journal fristpage311
journal lastpage313
identifier eissn1528-8951
keywordsElasticity
keywordsMeasurement AND Trachea
treeJournal of Biomechanical Engineering:;1982:;volume( 104 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record