    A Yaw-Insensitive Static Pressure Probe

    Source: Journal of Fluids Engineering:;1978:;volume( 100 ):;issue: 002::page 229
    Author:
    L. J. Huey
    DOI: 10.1115/1.3448635
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper reviews the development and testing of a static pressure probe which is relatively insensitive to yaw angle. The probe averages the pressure along an equatorial line on a sphere immersed in a flowing fluid such that the average measured pressure is the static pressure. The probe can be rotated up to ± 30 deg from the velocity vector with little error in the static pressure reading.
    keyword(s): Pressure , Probes , Yaw , Fluids , Testing AND Errors ,
    • Download: (272.5Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      A Yaw-Insensitive Static Pressure Probe

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/91196
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorL. J. Huey
    date accessioned2017-05-08T23:05:06Z
    date available2017-05-08T23:05:06Z
    date copyrightJune, 1978
    date issued1978
    identifier issn0098-2202
    identifier otherJFEGA4-26933#229_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/91196
    description abstractThis paper reviews the development and testing of a static pressure probe which is relatively insensitive to yaw angle. The probe averages the pressure along an equatorial line on a sphere immersed in a flowing fluid such that the average measured pressure is the static pressure. The probe can be rotated up to ± 30 deg from the velocity vector with little error in the static pressure reading.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Yaw-Insensitive Static Pressure Probe
    typeJournal Paper
    journal volume100
    journal issue2
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.3448635
    journal fristpage229
    journal lastpage231
    identifier eissn1528-901X
    keywordsPressure
    keywordsProbes
    keywordsYaw
    keywordsFluids
    keywordsTesting AND Errors
    treeJournal of Fluids Engineering:;1978:;volume( 100 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian