Effect of Rapid Steam Take-Off on Natural Circulation and Water Level in BoilersSource: Journal of Engineering for Gas Turbines and Power:;1975:;volume( 097 ):;issue: 004::page 645Author:K. L. Poon
DOI: 10.1115/1.3446082Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: A theory is presented for predicting the transient behavior of bubbles in the downcomer and riser loop. It is found that a sudden drop in boiler pressure could seriously reduce the circulation velocity and this is attributed to steam formation in the downcomer tube. The reduction of the circulation velocity tends to prolong existence of individual bubbles in the water phase and therefore increases the water level swell. Transient behavior of circulation velocity in the riser, and water level responses in the steam drum were measured in a two-tube experimental boiler following a step increase in steam control-valve opening for various boiler pressures.
keyword(s): Boilers , Steam , Water , Bubbles , Pipeline risers , Valves , Pressure AND Drops ,
|
Show full item record
| contributor author | K. L. Poon | |
| date accessioned | 2017-05-08T22:58:26Z | |
| date available | 2017-05-08T22:58:26Z | |
| date copyright | October, 1975 | |
| date issued | 1975 | |
| identifier issn | 1528-8919 | |
| identifier other | JETPEZ-26720#645_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/87386 | |
| description abstract | A theory is presented for predicting the transient behavior of bubbles in the downcomer and riser loop. It is found that a sudden drop in boiler pressure could seriously reduce the circulation velocity and this is attributed to steam formation in the downcomer tube. The reduction of the circulation velocity tends to prolong existence of individual bubbles in the water phase and therefore increases the water level swell. Transient behavior of circulation velocity in the riser, and water level responses in the steam drum were measured in a two-tube experimental boiler following a step increase in steam control-valve opening for various boiler pressures. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Effect of Rapid Steam Take-Off on Natural Circulation and Water Level in Boilers | |
| type | Journal Paper | |
| journal volume | 97 | |
| journal issue | 4 | |
| journal title | Journal of Engineering for Gas Turbines and Power | |
| identifier doi | 10.1115/1.3446082 | |
| journal fristpage | 645 | |
| journal lastpage | 654 | |
| identifier eissn | 0742-4795 | |
| keywords | Boilers | |
| keywords | Steam | |
| keywords | Water | |
| keywords | Bubbles | |
| keywords | Pipeline risers | |
| keywords | Valves | |
| keywords | Pressure AND Drops | |
| tree | Journal of Engineering for Gas Turbines and Power:;1975:;volume( 097 ):;issue: 004 | |
| contenttype | Fulltext |