    Facade Topography in Masonry Failure Investigation

    Source: Journal of Construction Engineering and Management:;1984:;Volume ( 110 ):;issue: 002
    Author:
    Clayford T. Grimm
    DOI: 10.1061/(ASCE)0733-9364(1984)110:2(145)
    Publisher: American Society of Civil Engineers
    Abstract: Masonry failure investigation often requires the documentation of the surface condition of walls. The types of information required for a masonry surface condition survey are Ksted. Among these is surface topography to define the locations and magnitude of lateral displacement and misplacement of the facade. A method is described for determining facade topography from a distance, i.e. from the ground and without touching the facade. The method has been tested and found useful.
    • Download: (496.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Facade Topography in Masonry Failure Investigation

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/80174
    Collections
    • Journal of Construction Engineering and Management

    Show full item record

    contributor authorClayford T. Grimm
    date accessioned2017-05-08T22:24:54Z
    date available2017-05-08T22:24:54Z
    date copyrightMarch 1984
    date issued1984
    identifier other%28asce%290733-9364%281984%29110%3A2%28145%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/80174
    description abstractMasonry failure investigation often requires the documentation of the surface condition of walls. The types of information required for a masonry surface condition survey are Ksted. Among these is surface topography to define the locations and magnitude of lateral displacement and misplacement of the facade. A method is described for determining facade topography from a distance, i.e. from the ground and without touching the facade. The method has been tested and found useful.
    publisherAmerican Society of Civil Engineers
    titleFacade Topography in Masonry Failure Investigation
    typeJournal Paper
    journal volume110
    journal issue2
    journal titleJournal of Construction Engineering and Management
    identifier doi10.1061/(ASCE)0733-9364(1984)110:2(145)
    treeJournal of Construction Engineering and Management:;1984:;Volume ( 110 ):;issue: 002
    contenttypeFulltext