    Behavior of a Continuous Composite Box Girder with a Prefabricated Prestressed-Concrete Slab in Its Hogging-Moment Region

    Source: Journal of Bridge Engineering:;2015:;Volume ( 020 ):;issue: 008
    Author:
    Qingtian
    ,
    Su
    ,
    Guotao
    ,
    Yang
    ,
    Mark A.
    ,
    Bradford
    DOI: 10.1061/(ASCE)BE.1943-5592.0000698
    Publisher: American Society of Civil Engineers
    Abstract: The application of prestress is a very effective way to prevent the cracking of the concrete slab in the negative-moment region of continuous composite girders, and using a prefabricated prestressed-concrete slab in this region is an easier option than posttensioning. To elucidate the structural response of a continuous composite box girder with a prefabricated prestressed-concrete slab, two large, 18-m-long specimens were fabricated and tested under short-term loading, and the results are reported in this paper. One, a control specimen, was a conventional composite girder with its concrete slab cast in situ, whereas the other was a composite box girder with a prefabricated prestressed-concrete slab in the negative-moment region. The relative slip between the steel girder and the concrete slab; the load-deflection response; the distribution of strain in the steel girder, reinforcement, and concrete slab; as well as the crack widths in the concrete slab were measured during the tests. The paper shows that, although the ultimate strengths of the two specimens are almost the same, the initial cracking load and serviceability limit state load of the specimen with a prefabricated prestressed-concrete slab are 3.16 and 2.61 times, respectively, those of the specimen with a conventional concrete slab. It is also shown that simple linear-elastic analysis leads to a close prediction of the load for initial cracking. By comparison, a continuous composite bridge beam with a prefabricated prestressed slab over its internal support is stiffer and less likely to experience the ingress of corrosive materials than one with a conventional RC slab is.
    • Download: (2.469Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Behavior of a Continuous Composite Box Girder with a Prefabricated Prestressed-Concrete Slab in Its Hogging-Moment Region

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/79721
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorQingtian
    contributor authorSu
    contributor authorGuotao
    contributor authorYang
    contributor authorMark A.
    contributor authorBradford
    date accessioned2017-05-08T22:24:03Z
    date available2017-05-08T22:24:03Z
    date copyrightAugust 2015
    date issued2015
    identifier other44024845.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/79721
    description abstractThe application of prestress is a very effective way to prevent the cracking of the concrete slab in the negative-moment region of continuous composite girders, and using a prefabricated prestressed-concrete slab in this region is an easier option than posttensioning. To elucidate the structural response of a continuous composite box girder with a prefabricated prestressed-concrete slab, two large, 18-m-long specimens were fabricated and tested under short-term loading, and the results are reported in this paper. One, a control specimen, was a conventional composite girder with its concrete slab cast in situ, whereas the other was a composite box girder with a prefabricated prestressed-concrete slab in the negative-moment region. The relative slip between the steel girder and the concrete slab; the load-deflection response; the distribution of strain in the steel girder, reinforcement, and concrete slab; as well as the crack widths in the concrete slab were measured during the tests. The paper shows that, although the ultimate strengths of the two specimens are almost the same, the initial cracking load and serviceability limit state load of the specimen with a prefabricated prestressed-concrete slab are 3.16 and 2.61 times, respectively, those of the specimen with a conventional concrete slab. It is also shown that simple linear-elastic analysis leads to a close prediction of the load for initial cracking. By comparison, a continuous composite bridge beam with a prefabricated prestressed slab over its internal support is stiffer and less likely to experience the ingress of corrosive materials than one with a conventional RC slab is.
    publisherAmerican Society of Civil Engineers
    titleBehavior of a Continuous Composite Box Girder with a Prefabricated Prestressed-Concrete Slab in Its Hogging-Moment Region
    typeJournal Paper
    journal volume20
    journal issue8
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)BE.1943-5592.0000698
    treeJournal of Bridge Engineering:;2015:;Volume ( 020 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian