    Dynamic Commercial Façades versus Traditional Construction: Energy Performance and Comparative Analysis

    Source: Journal of Energy Engineering:;2015:;Volume ( 141 ):;issue: 004
    Author:
    Hui Shen
    ,
    Athanasios Tzempelikos
    ,
    Anna Maria Atzeri
    ,
    Andrea Gasparella
    ,
    Francesca Cappelletti
    DOI: 10.1061/(ASCE)EY.1943-7897.0000225
    Publisher: American Society of Civil Engineers
    Abstract: Driven by architectural trends and the need to maximize daylight, commercial building façades have become more transparent. High-performance façades include spectrally selective glazing systems, dynamic elements and insulated spandrel sections. Nevertheless, it is generally accepted that, compared to standard, traditional opaque construction, modern transparent envelopes result in increased overall energy use in these buildings. In this paper, the building façade is treated as a part of the building perimeter zone, which also includes electric lighting controls, shading attachments, HVAC components, and indoor environmental controls. Consequently, the objective is to balance the need for daylighting and view versus the need for controlling of solar gains and maintaining human comfort, while reducing energy demand for air conditioning and lighting. Key parameters in solving this problem are (1) technological advancements in glazing products, (2) utilization of dynamic building envelope components, and (3) lighting and HVAC controls. In order to demonstrate the potential of high-performance façades, a typical office building with large perimeter zones is used as an example. The basic model consists of standard brick exterior walls with 20% punched windows. Then, a comparative analysis is performed for a more transparent envelope with dynamic systems including shading and electric lighting controls, for the climates of Chicago and Rome. An integrated thermal-lighting model with flexible dynamic system controls, verified with commercial software, is expanded to simulate more complex façade controls for reducing glare problems while maximizing useful daylight. The results show the advantages of transparent façades with active systems, compared to traditional building envelopes. The more transparent building results in lower operational costs and source energy use, although total site energy use can be higher for heating-dominated climates.
    • Download: (3.305Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Dynamic Commercial Façades versus Traditional Construction: Energy Performance and Comparative Analysis

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/72232
    Collections
    • Journal of Energy Engineering

    Show full item record

    contributor authorHui Shen
    contributor authorAthanasios Tzempelikos
    contributor authorAnna Maria Atzeri
    contributor authorAndrea Gasparella
    contributor authorFrancesca Cappelletti
    date accessioned2017-05-08T22:08:40Z
    date available2017-05-08T22:08:40Z
    date copyrightDecember 2015
    date issued2015
    identifier other32921234.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/72232
    description abstractDriven by architectural trends and the need to maximize daylight, commercial building façades have become more transparent. High-performance façades include spectrally selective glazing systems, dynamic elements and insulated spandrel sections. Nevertheless, it is generally accepted that, compared to standard, traditional opaque construction, modern transparent envelopes result in increased overall energy use in these buildings. In this paper, the building façade is treated as a part of the building perimeter zone, which also includes electric lighting controls, shading attachments, HVAC components, and indoor environmental controls. Consequently, the objective is to balance the need for daylighting and view versus the need for controlling of solar gains and maintaining human comfort, while reducing energy demand for air conditioning and lighting. Key parameters in solving this problem are (1) technological advancements in glazing products, (2) utilization of dynamic building envelope components, and (3) lighting and HVAC controls. In order to demonstrate the potential of high-performance façades, a typical office building with large perimeter zones is used as an example. The basic model consists of standard brick exterior walls with 20% punched windows. Then, a comparative analysis is performed for a more transparent envelope with dynamic systems including shading and electric lighting controls, for the climates of Chicago and Rome. An integrated thermal-lighting model with flexible dynamic system controls, verified with commercial software, is expanded to simulate more complex façade controls for reducing glare problems while maximizing useful daylight. The results show the advantages of transparent façades with active systems, compared to traditional building envelopes. The more transparent building results in lower operational costs and source energy use, although total site energy use can be higher for heating-dominated climates.
    publisherAmerican Society of Civil Engineers
    titleDynamic Commercial Façades versus Traditional Construction: Energy Performance and Comparative Analysis
    typeJournal Paper
    journal volume141
    journal issue4
    journal titleJournal of Energy Engineering
    identifier doi10.1061/(ASCE)EY.1943-7897.0000225
    treeJournal of Energy Engineering:;2015:;Volume ( 141 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian