    Thin-layer Micro-element Method for Cohesive Soil Passive Earth Pressure Determination on Retaining Walls

    Source: Journal of Highway and Transportation Research and Development (English Edition):;2012:;Volume ( 006 ):;issue: 002
    Author:
    Lin Yuliang
    ,
    Yang Guolin
    ,
    Huang Xiangjing
    DOI: 10.1061/JHTRCQ.0000120
    Publisher: American Society of Civil Engineers
    Abstract: A thin-layer micro-element method that is based on the thought of horizontal slice method was developed to deduce the passive earth pressure of cohesive soil by considering the retaining wall height, wall back batter angle, filler elevation angle, equispaced overload, bulk density, internal friction angle, cohesion, and the external friction angle between the soil and the wall back. An explicit solution of the critical rupture angle was obtained using the graphic method. The effects of the aforementioned parameters on the critical rupture angle, the passive earth pressure distribution, and the resultant force of this pressure as well as its application position were analyzed. The results show that (1) the distribution of the passive earth pressure along the wall back is non-linear; (2) Coulomb and Rankine’s theories on passive earth pressure are special cases of the passive earth pressure formula under the corresponding simplified assumptions; and (3) the passive earth pressure and its distribution are greatly affected by factors such as the wall back batter angle, filler elevation angle, equispaced overload, soil cohesion, internal friction angle, and external friction angle of the soil. However, the bulk density has negligible effect on the application position of the resultant force of the passive earth pressure.
    • Download: (586.1Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Thin-layer Micro-element Method for Cohesive Soil Passive Earth Pressure Determination on Retaining Walls

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/70670
    Collections
    • Journal of Highway and Transportation Research and Development (English Edition)

    Show full item record

    contributor authorLin Yuliang
    contributor authorYang Guolin
    contributor authorHuang Xiangjing
    date accessioned2017-05-08T22:04:48Z
    date available2017-05-08T22:04:48Z
    date copyrightJune 2012
    date issued2012
    identifier otherjhtrcq%2E0000120.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/70670
    description abstractA thin-layer micro-element method that is based on the thought of horizontal slice method was developed to deduce the passive earth pressure of cohesive soil by considering the retaining wall height, wall back batter angle, filler elevation angle, equispaced overload, bulk density, internal friction angle, cohesion, and the external friction angle between the soil and the wall back. An explicit solution of the critical rupture angle was obtained using the graphic method. The effects of the aforementioned parameters on the critical rupture angle, the passive earth pressure distribution, and the resultant force of this pressure as well as its application position were analyzed. The results show that (1) the distribution of the passive earth pressure along the wall back is non-linear; (2) Coulomb and Rankine’s theories on passive earth pressure are special cases of the passive earth pressure formula under the corresponding simplified assumptions; and (3) the passive earth pressure and its distribution are greatly affected by factors such as the wall back batter angle, filler elevation angle, equispaced overload, soil cohesion, internal friction angle, and external friction angle of the soil. However, the bulk density has negligible effect on the application position of the resultant force of the passive earth pressure.
    publisherAmerican Society of Civil Engineers
    titleThin-layer Micro-element Method for Cohesive Soil Passive Earth Pressure Determination on Retaining Walls
    typeJournal Paper
    journal volume6
    journal issue2
    journal titleJournal of Highway and Transportation Research and Development (English Edition)
    identifier doi10.1061/JHTRCQ.0000120
    treeJournal of Highway and Transportation Research and Development (English Edition):;2012:;Volume ( 006 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian