    Effects of Tendon Spacing on In-Plane Behavior of Posttensioned Masonry Walls

    Source: Journal of Structural Engineering:;2014:;Volume ( 140 ):;issue: 004
    Author:
    Dongun Ryu
    ,
    Anil C. Wijeyewickrema
    ,
    Mohamed A. ElGawady
    ,
    M. A. K. M. Madurapperuma
    DOI: 10.1061/(ASCE)ST.1943-541X.0000849
    Publisher: American Society of Civil Engineers
    Abstract: In-plane behavior of unbonded posttensioned clay brick masonry walls are investigated using detailed finite-element (FE) models. FE models of three walls having different aspect ratios of 1.50, 1.00, and 0.67 are developed. Effects of tendon spacing on in-plane behavior of these walls are investigated using different tendon spacings ranging from 0.61 m (2 ft) to 3.81 m (12.5 ft). In addition, the effects of having different horizontal reinforcement ratios of 0%, 0.1%, and 0.5% on the in-plane behavior of the walls were investigated. The stresses in the tendons are calculated using different approaches, and then the flexural strength of each wall is calculated and compared with those obtained from the numerical analysis. The simulation results show that for spacing between tendons up to 2 m (6.6 ft), ignoring the elongation in the tendon in calculating the flexural strength results in too conservative design. For these walls, it is more appropriate to use equations provided by the Masonry Standard Joint Committee for out-of-plane behavior of masonry walls. For spacing between tendons greater than 2 m (6.6 ft), ignoring the elongation in tendons and using the effective posttensioning force to calculate the flexural strength agree well with those obtained from the FE analyses. The FE analyses showed that adding shear reinforcement for walls with tendon spacing smaller than 2 m (6.6 ft) does not improve the shear strength of the walls. However, for walls having spacing between tendons greater than 2 m (6.6 ft), even with small amount of shear reinforcement, the shear strength increases significantly.
    • Download: (3.615Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Effects of Tendon Spacing on In-Plane Behavior of Posttensioned Masonry Walls

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/68787
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorDongun Ryu
    contributor authorAnil C. Wijeyewickrema
    contributor authorMohamed A. ElGawady
    contributor authorM. A. K. M. Madurapperuma
    date accessioned2017-05-08T22:00:54Z
    date available2017-05-08T22:00:54Z
    date copyrightApril 2014
    date issued2014
    identifier other%28asce%29st%2E1943-541x%2E0000891.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/68787
    description abstractIn-plane behavior of unbonded posttensioned clay brick masonry walls are investigated using detailed finite-element (FE) models. FE models of three walls having different aspect ratios of 1.50, 1.00, and 0.67 are developed. Effects of tendon spacing on in-plane behavior of these walls are investigated using different tendon spacings ranging from 0.61 m (2 ft) to 3.81 m (12.5 ft). In addition, the effects of having different horizontal reinforcement ratios of 0%, 0.1%, and 0.5% on the in-plane behavior of the walls were investigated. The stresses in the tendons are calculated using different approaches, and then the flexural strength of each wall is calculated and compared with those obtained from the numerical analysis. The simulation results show that for spacing between tendons up to 2 m (6.6 ft), ignoring the elongation in the tendon in calculating the flexural strength results in too conservative design. For these walls, it is more appropriate to use equations provided by the Masonry Standard Joint Committee for out-of-plane behavior of masonry walls. For spacing between tendons greater than 2 m (6.6 ft), ignoring the elongation in tendons and using the effective posttensioning force to calculate the flexural strength agree well with those obtained from the FE analyses. The FE analyses showed that adding shear reinforcement for walls with tendon spacing smaller than 2 m (6.6 ft) does not improve the shear strength of the walls. However, for walls having spacing between tendons greater than 2 m (6.6 ft), even with small amount of shear reinforcement, the shear strength increases significantly.
    publisherAmerican Society of Civil Engineers
    titleEffects of Tendon Spacing on In-Plane Behavior of Posttensioned Masonry Walls
    typeJournal Paper
    journal volume140
    journal issue4
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0000849
    treeJournal of Structural Engineering:;2014:;Volume ( 140 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian