YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Structural Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Collapse Testing and Analysis of a Light-Frame Wood Garage Wall

    Source: Journal of Structural Engineering:;2012:;Volume ( 138 ):;issue: 004
    Author:
    John W. van de Lindt
    ,
    Shiling Pei
    ,
    Weichiang Pang
    ,
    Seyed Masood Hassanzadeh Shirazi
    DOI: 10.1061/(ASCE)ST.1943-541X.0000472
    Publisher: American Society of Civil Engineers
    Abstract: Light-frame wood (woodframe) buildings have been tested at full-scale sparingly around the world, primarily due to the cost associated with such testing and a general lack of facilities large enough to test at system level. The data from the tests that have been performed are used to help develop nonlinear time history analysis models that can predict the behavior of woodframe buildings during strong ground shaking. It is difficult to test buildings to the point of collapse because such tests can damage costly test equipment, i.e., the shake table. This paper presents the results of a dynamic collapse test on a light-frame wood garage wall and the results of a numerical model to simulate the wall behavior all the way to the collapse point. The tested wall was heavily damaged as a result of subjecting it to a ground motion recorded during the 1995 Kobe earthquake. Then, 85% of a near-fault ground motion recording from the Northridge earthquake was used, which immediately collapsed the test specimen. A specialized wood shear wall analysis program, formulated using a corotational formulation and large deformation theory, was utilized to model the garage wall. The numerical model provided a good prediction (predicted the peak wall displacements to within 15% of the measured values), but as a direct result of the observed failure mechanism of the wall, it was determined that additional contact elements were needed in the model. Failure was observed at the sill plate of the garage wall returns and also in the sheathing due to a moment failure where the header connected to the wall returns. Finally, it was observed that variability in the stiffness of the hold-down connections has a significant influence on the uplift predictions.
    • Download: (468.9Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Collapse Testing and Analysis of a Light-Frame Wood Garage Wall

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/68382
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorJohn W. van de Lindt
    contributor authorShiling Pei
    contributor authorWeichiang Pang
    contributor authorSeyed Masood Hassanzadeh Shirazi
    date accessioned2017-05-08T21:59:37Z
    date available2017-05-08T21:59:37Z
    date copyrightApril 2012
    date issued2012
    identifier other%28asce%29st%2E1943-541x%2E0000515.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/68382
    description abstractLight-frame wood (woodframe) buildings have been tested at full-scale sparingly around the world, primarily due to the cost associated with such testing and a general lack of facilities large enough to test at system level. The data from the tests that have been performed are used to help develop nonlinear time history analysis models that can predict the behavior of woodframe buildings during strong ground shaking. It is difficult to test buildings to the point of collapse because such tests can damage costly test equipment, i.e., the shake table. This paper presents the results of a dynamic collapse test on a light-frame wood garage wall and the results of a numerical model to simulate the wall behavior all the way to the collapse point. The tested wall was heavily damaged as a result of subjecting it to a ground motion recorded during the 1995 Kobe earthquake. Then, 85% of a near-fault ground motion recording from the Northridge earthquake was used, which immediately collapsed the test specimen. A specialized wood shear wall analysis program, formulated using a corotational formulation and large deformation theory, was utilized to model the garage wall. The numerical model provided a good prediction (predicted the peak wall displacements to within 15% of the measured values), but as a direct result of the observed failure mechanism of the wall, it was determined that additional contact elements were needed in the model. Failure was observed at the sill plate of the garage wall returns and also in the sheathing due to a moment failure where the header connected to the wall returns. Finally, it was observed that variability in the stiffness of the hold-down connections has a significant influence on the uplift predictions.
    publisherAmerican Society of Civil Engineers
    titleCollapse Testing and Analysis of a Light-Frame Wood Garage Wall
    typeJournal Paper
    journal volume138
    journal issue4
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0000472
    treeJournal of Structural Engineering:;2012:;Volume ( 138 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian