YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Pipeline Systems Engineering and Practice
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Pipeline Systems Engineering and Practice
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Pipe Efficiency Analysis at a Water Utility

    Source: Journal of Pipeline Systems Engineering and Practice:;2011:;Volume ( 002 ):;issue: 001
    Author:
    Amarjit Singh
    ,
    Stacy Adachi
    DOI: 10.1061/(ASCE)PS.1949-1204.0000071
    Publisher: American Society of Civil Engineers
    Abstract: A water utility company has many actions and decisions to take in order to run operations efficiently and effectively. One of them is to decide which types of pipe(s) to install as they do not all perform the same. Because these pipes may remain installed underground for more than 100 years, the decision to install is substantially binding. The pipe types considered here are ductile iron (DI), cast iron, PVC, and concrete cylinder (CC). The approach was to study cost and quality control measures and then apply data envelopment analysis in linear programming to determine the relative inefficiency of the specific pipe type in comparison to the rest of the pipe system. Data were taken from the main-break database and records and reports published by the Honolulu Board of Water Supply. Quality control measures evaluated included availability and reliability at the system and individual levels. It was determined that CC pipes were more inefficient than the others. Multiple scenarios of output measures were evaluated, such as combinations of system and individual levels, availability, and reliability. In all such evaluations, it was conclusively seen that CC pipes were relatively inefficient. Consequently, it is recommended the utility plan to replace CC pipes with corresponding DI and PVC piping.
    • Download: (142.1Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Pipe Efficiency Analysis at a Water Utility

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/67623
    Collections
    • Journal of Pipeline Systems Engineering and Practice

    Show full item record

    contributor authorAmarjit Singh
    contributor authorStacy Adachi
    date accessioned2017-05-08T21:58:00Z
    date available2017-05-08T21:58:00Z
    date copyrightFebruary 2011
    date issued2011
    identifier other%28asce%29ps%2E1949-1204%2E0000116.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/67623
    description abstractA water utility company has many actions and decisions to take in order to run operations efficiently and effectively. One of them is to decide which types of pipe(s) to install as they do not all perform the same. Because these pipes may remain installed underground for more than 100 years, the decision to install is substantially binding. The pipe types considered here are ductile iron (DI), cast iron, PVC, and concrete cylinder (CC). The approach was to study cost and quality control measures and then apply data envelopment analysis in linear programming to determine the relative inefficiency of the specific pipe type in comparison to the rest of the pipe system. Data were taken from the main-break database and records and reports published by the Honolulu Board of Water Supply. Quality control measures evaluated included availability and reliability at the system and individual levels. It was determined that CC pipes were more inefficient than the others. Multiple scenarios of output measures were evaluated, such as combinations of system and individual levels, availability, and reliability. In all such evaluations, it was conclusively seen that CC pipes were relatively inefficient. Consequently, it is recommended the utility plan to replace CC pipes with corresponding DI and PVC piping.
    publisherAmerican Society of Civil Engineers
    titlePipe Efficiency Analysis at a Water Utility
    typeJournal Paper
    journal volume2
    journal issue1
    journal titleJournal of Pipeline Systems Engineering and Practice
    identifier doi10.1061/(ASCE)PS.1949-1204.0000071
    treeJournal of Pipeline Systems Engineering and Practice:;2011:;Volume ( 002 ):;issue: 001
    contenttypeFulltext