    Archive

    Laboratory Observation of the Response of a Buried Pipeline to Freezing Rubber-Sand Backfill

    Source: Journal of Materials in Civil Engineering:;2010:;Volume ( 022 ):;issue: 009
    Author:
    Martin Christ
    ,
    Jun-Boum Park
    ,
    Seung-Seo Hong
    DOI: 10.1061/(ASCE)MT.1943-5533.0000090
    Publisher: American Society of Civil Engineers
    Abstract: This paper addresses the potential use of granulated rubber as backfill material for buried pipelines in cold regions. An experiment on a laboratory scale buried pipe was conducted to evaluate the pipe-backfill interaction upon freezing. Two backfill materials were employed. In Case 1, sand was used as backfill material. In Case 2, granulated rubber was mixed with sand. Induced circumferential and longitudinal strains along the pipe were measured with movement of the freezing front into the backfill and an estimate of the freezing soil pressure was obtained based on the measured pipe strain. Experimental results showed that the behavior of the buried pipe was influenced by the progression of the freezing front and type of backfill material. Cold temperatures advanced faster into the sand backfill compared to the rubber-sand backfill due to the good thermal characteristics of rubber. Circumferential strains increased in both backfills indicating the development of freezing soil pressure in the backfill. Dominant vertical compressive strains were observed at 0° and 180° in both backfills. A significant reduction in strain and pressure exerted on the pipe upon freezing in the rubber-sand backfill was confirmed and the application of rubber mixed with sand as backfill material is possible.
    • Download: (179.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Laboratory Observation of the Response of a Buried Pipeline to Freezing Rubber-Sand Backfill

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/66432
    Collections
    • Journal of Materials in Civil Engineering

    Show full item record

    contributor authorMartin Christ
    contributor authorJun-Boum Park
    contributor authorSeung-Seo Hong
    date accessioned2017-05-08T21:55:08Z
    date available2017-05-08T21:55:08Z
    date copyrightSeptember 2010
    date issued2010
    identifier other%28asce%29mt%2E1943-5533%2E0000122.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/66432
    description abstractThis paper addresses the potential use of granulated rubber as backfill material for buried pipelines in cold regions. An experiment on a laboratory scale buried pipe was conducted to evaluate the pipe-backfill interaction upon freezing. Two backfill materials were employed. In Case 1, sand was used as backfill material. In Case 2, granulated rubber was mixed with sand. Induced circumferential and longitudinal strains along the pipe were measured with movement of the freezing front into the backfill and an estimate of the freezing soil pressure was obtained based on the measured pipe strain. Experimental results showed that the behavior of the buried pipe was influenced by the progression of the freezing front and type of backfill material. Cold temperatures advanced faster into the sand backfill compared to the rubber-sand backfill due to the good thermal characteristics of rubber. Circumferential strains increased in both backfills indicating the development of freezing soil pressure in the backfill. Dominant vertical compressive strains were observed at 0° and 180° in both backfills. A significant reduction in strain and pressure exerted on the pipe upon freezing in the rubber-sand backfill was confirmed and the application of rubber mixed with sand as backfill material is possible.
    publisherAmerican Society of Civil Engineers
    titleLaboratory Observation of the Response of a Buried Pipeline to Freezing Rubber-Sand Backfill
    typeJournal Paper
    journal volume22
    journal issue9
    journal titleJournal of Materials in Civil Engineering
    identifier doi10.1061/(ASCE)MT.1943-5533.0000090
    treeJournal of Materials in Civil Engineering:;2010:;Volume ( 022 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace