    Cap-Orifice as a Flow Regulator for Rain Garden Design

    Source: Journal of Irrigation and Drainage Engineering:;2012:;Volume ( 138 ):;issue: 002
    Author:
    James C. Y. Guo
    DOI: 10.1061/(ASCE)IR.1943-4774.0000399
    Publisher: American Society of Civil Engineers
    Abstract: Rain gardens have been recognized as an effective device for on-site runoff volume reduction and storm water quality enhancement. A rain garden is designed as an infiltration basin with a shallow, wide water storage volume. The subbase underneath the basin bottom is structured as a two-layered filtering medium. The upper sand layer provides the required filtering process and then the lower gravel layer provides a reservoir for a gradual release of the stored water through a perforated underdrain pipe. A newly constructed rain garden can have a high-infiltration capacity. After several years of service, the accumulation of solids intercepted in the filtering layer will develop a clogging effect or the infiltration capacity in the subbase continues decreasing. When the drain time exceeds the safety criteria, the rain garden needs to be replaced. Coping with a decaying infiltration rate, a rain garden needs to reduce its flow release in the early years. In this study, it is suggested that a cap-orifice be installed at the exit of the underdrain pipe. This cap-orifice is sized to reduce the initial infiltrating rate in the early years and then to work with the clogged infiltration rate throughout the life cycle of a rain garden. The design methodology presented in this paper allows the engineer to size this cap-orifice according to the decay of infiltration rate, required drain time, and allowable flow release.
    • Download: (338.5Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Cap-Orifice as a Flow Regulator for Rain Garden Design

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/65301
    Collections
    • Journal of Irrigation and Drainage Engineering

    Show full item record

    contributor authorJames C. Y. Guo
    date accessioned2017-05-08T21:53:04Z
    date available2017-05-08T21:53:04Z
    date copyrightFebruary 2012
    date issued2012
    identifier other%28asce%29ir%2E1943-4774%2E0000428.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/65301
    description abstractRain gardens have been recognized as an effective device for on-site runoff volume reduction and storm water quality enhancement. A rain garden is designed as an infiltration basin with a shallow, wide water storage volume. The subbase underneath the basin bottom is structured as a two-layered filtering medium. The upper sand layer provides the required filtering process and then the lower gravel layer provides a reservoir for a gradual release of the stored water through a perforated underdrain pipe. A newly constructed rain garden can have a high-infiltration capacity. After several years of service, the accumulation of solids intercepted in the filtering layer will develop a clogging effect or the infiltration capacity in the subbase continues decreasing. When the drain time exceeds the safety criteria, the rain garden needs to be replaced. Coping with a decaying infiltration rate, a rain garden needs to reduce its flow release in the early years. In this study, it is suggested that a cap-orifice be installed at the exit of the underdrain pipe. This cap-orifice is sized to reduce the initial infiltrating rate in the early years and then to work with the clogged infiltration rate throughout the life cycle of a rain garden. The design methodology presented in this paper allows the engineer to size this cap-orifice according to the decay of infiltration rate, required drain time, and allowable flow release.
    publisherAmerican Society of Civil Engineers
    titleCap-Orifice as a Flow Regulator for Rain Garden Design
    typeJournal Paper
    journal volume138
    journal issue2
    journal titleJournal of Irrigation and Drainage Engineering
    identifier doi10.1061/(ASCE)IR.1943-4774.0000399
    treeJournal of Irrigation and Drainage Engineering:;2012:;Volume ( 138 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian