    Archive

    Performance of a Combined Natural Wastewater Treatment System in West Texas

    Source: Journal of Irrigation and Drainage Engineering:;2010:;Volume ( 136 ):;issue: 003
    Author:
    Runbin Duan
    ,
    Clifford B. Fedler
    DOI: 10.1061/(ASCE)IR.1943-4774.0000154
    Publisher: American Society of Civil Engineers
    Abstract: A study of performance of a combined natural wastewater treatment system was conducted in an arid and semiarid area of West Texas from October 2005 to September 2007. This study investigated the organic matter and nitrogen removal capability in a municipal wastewater land application system following a pond system. Municipal wastewater from the city of Littlefield, Tex. was pretreated by a pond system, and the secondary wastewater effluent from the pond system was surface applied to sprayfield at the wastewater treatment plant and the city farm. The 16 lysimeters were installed in situ to collect the leached water passing the grass root zone. The water samples were taken from the storage pond and the lysimeters for analysis of chemical oxygen demand (COD), total nitrogen, nitrate nitrogen, and ammonia nitrogen. The data show that the pond system played an important role in the treatment. The pond system pretreated COD in the municipal wastewater to the range of 10 to 127 mg/L, total nitrogen to the range of 5 to 19 mg/L, nitrate nitrogen to the range of 2.4 to 8.2 mg/L, and ammonia nitrogen to the range of 0.01 to 6.4 mg/L. The average mass removals and cumulative mass removals were 94 and 96% for total nitrogen, 92 and 93% for nitrate nitrogen, and 96 and 100% for ammonia nitrogen, respectively. There was no potential nitrogen contamination to groundwater found during the research period. The study illustrated that this type of combined natural wastewater treatment system can be used to effectively treat and safely dispose municipal wastewater, and save freshwater used for agricultural irrigation in arid and semiarid area.
    • Download: (368.9Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Performance of a Combined Natural Wastewater Treatment System in West Texas

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/65039
    Collections
    • Journal of Irrigation and Drainage Engineering

    Show full item record

    contributor authorRunbin Duan
    contributor authorClifford B. Fedler
    date accessioned2017-05-08T21:52:39Z
    date available2017-05-08T21:52:39Z
    date copyrightMarch 2010
    date issued2010
    identifier other%28asce%29ir%2E1943-4774%2E0000182.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/65039
    description abstractA study of performance of a combined natural wastewater treatment system was conducted in an arid and semiarid area of West Texas from October 2005 to September 2007. This study investigated the organic matter and nitrogen removal capability in a municipal wastewater land application system following a pond system. Municipal wastewater from the city of Littlefield, Tex. was pretreated by a pond system, and the secondary wastewater effluent from the pond system was surface applied to sprayfield at the wastewater treatment plant and the city farm. The 16 lysimeters were installed in situ to collect the leached water passing the grass root zone. The water samples were taken from the storage pond and the lysimeters for analysis of chemical oxygen demand (COD), total nitrogen, nitrate nitrogen, and ammonia nitrogen. The data show that the pond system played an important role in the treatment. The pond system pretreated COD in the municipal wastewater to the range of 10 to 127 mg/L, total nitrogen to the range of 5 to 19 mg/L, nitrate nitrogen to the range of 2.4 to 8.2 mg/L, and ammonia nitrogen to the range of 0.01 to 6.4 mg/L. The average mass removals and cumulative mass removals were 94 and 96% for total nitrogen, 92 and 93% for nitrate nitrogen, and 96 and 100% for ammonia nitrogen, respectively. There was no potential nitrogen contamination to groundwater found during the research period. The study illustrated that this type of combined natural wastewater treatment system can be used to effectively treat and safely dispose municipal wastewater, and save freshwater used for agricultural irrigation in arid and semiarid area.
    publisherAmerican Society of Civil Engineers
    titlePerformance of a Combined Natural Wastewater Treatment System in West Texas
    typeJournal Paper
    journal volume136
    journal issue3
    journal titleJournal of Irrigation and Drainage Engineering
    identifier doi10.1061/(ASCE)IR.1943-4774.0000154
    treeJournal of Irrigation and Drainage Engineering:;2010:;Volume ( 136 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian