YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Energy Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Energy Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Investigation of Performance of Heat Pipe as Heat Exchanger Using Alternative Refrigerants

    Source: Journal of Energy Engineering:;2013:;Volume ( 139 ):;issue: 001
    Author:
    M. A. M. Hassan
    DOI: 10.1061/(ASCE)EY.1943-7897.0000091
    Publisher: American Society of Civil Engineers
    Abstract: An experimental and theoretical study was performed to investigate the thermal performance of heat pipes as a heat exchanger. A series of experiments was conducted using R410A, R134a, R22, and R407C as working fluids. The dimensions of the heat pipes that were used in the test rig included 660 mm length, 20 mm outer diameter and 4 mm fin spacing with staggered arrangements. During the tests, the dry bulb temperature of the evaporator inlet was varied from 35 to 55°C and the condenser inlet dry bulb temperature was varied from 20 to 25°C. The influence of face velocity on the performance of the heat pipe heat exchanger was also studied. Many investigations were made to obtain the thermal performance and to ensure efficient and reliable operation of the heat pipe heat exchanger, and the results are presented in the present paper. Tests showed that using R410A, R134a, and R22 provided comparative results, whereas R407C was the least effective. The experimental thermal effectiveness of the heat pipe heat exchanger obtained from the experiments varied between 25 and 70% for R410A, R134a, and R22, whereas the experimental thermal effectiveness of R407C varied between 15 and 50%. A computer simulation program based on the effectiveness method and the number of transfer units was developed to estimate the thermal performance of the heat pipe heat exchanger and to compare the theoretical and experimental results.
    • Download: (591.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Investigation of Performance of Heat Pipe as Heat Exchanger Using Alternative Refrigerants

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/61322
    Collections
    • Journal of Energy Engineering

    Show full item record

    contributor authorM. A. M. Hassan
    date accessioned2017-05-08T21:44:56Z
    date available2017-05-08T21:44:56Z
    date copyrightMarch 2013
    date issued2013
    identifier other%28asce%29ey%2E1943-7897%2E0000103.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/61322
    description abstractAn experimental and theoretical study was performed to investigate the thermal performance of heat pipes as a heat exchanger. A series of experiments was conducted using R410A, R134a, R22, and R407C as working fluids. The dimensions of the heat pipes that were used in the test rig included 660 mm length, 20 mm outer diameter and 4 mm fin spacing with staggered arrangements. During the tests, the dry bulb temperature of the evaporator inlet was varied from 35 to 55°C and the condenser inlet dry bulb temperature was varied from 20 to 25°C. The influence of face velocity on the performance of the heat pipe heat exchanger was also studied. Many investigations were made to obtain the thermal performance and to ensure efficient and reliable operation of the heat pipe heat exchanger, and the results are presented in the present paper. Tests showed that using R410A, R134a, and R22 provided comparative results, whereas R407C was the least effective. The experimental thermal effectiveness of the heat pipe heat exchanger obtained from the experiments varied between 25 and 70% for R410A, R134a, and R22, whereas the experimental thermal effectiveness of R407C varied between 15 and 50%. A computer simulation program based on the effectiveness method and the number of transfer units was developed to estimate the thermal performance of the heat pipe heat exchanger and to compare the theoretical and experimental results.
    publisherAmerican Society of Civil Engineers
    titleInvestigation of Performance of Heat Pipe as Heat Exchanger Using Alternative Refrigerants
    typeJournal Paper
    journal volume139
    journal issue1
    journal titleJournal of Energy Engineering
    identifier doi10.1061/(ASCE)EY.1943-7897.0000091
    treeJournal of Energy Engineering:;2013:;Volume ( 139 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش