    Design of Two-Layered Porous Landscaping Detention Basin

    Source: Journal of Environmental Engineering:;2009:;Volume ( 135 ):;issue: 012
    Author:
    J. C. Y. Guo
    ,
    S. M. Kocman
    ,
    A. Ramaswami
    DOI: 10.1061/(ASCE)EE.1943-7870.0000113
    Publisher: American Society of Civil Engineers
    Abstract: Under the mandate of the Federal Clean Water Act, porous landscaping detention (PLD) has been widely used to increase on-site infiltration. A PLD system consists of a surface storage basin and subsurface filtering layers. The major design parameters for a PLD system are the infiltration rate on the land surface and the seepage rate through the subsurface medium. A low infiltration rate leads to a sizable storage basin while a high infiltration rate results in standing water if the subsurface seepage does not sustain the surface loading. In this study, the design procedure of a PLD basin is revised to take both detention flow hydrology and seepage flow hydraulics into consideration. The design procedure begins with the basin sizing according to the on-site water quality control volume. The ratio of design infiltration rate to sand-mix hydraulic conductivity is the key factor to select the thickness of sand-mix layer underneath a porous bed. The total filtering thickness for both sand-mix and gravel layers is found to be related to the drain time and infiltration rate. The recommended sand-mix and granite gravel layers underneath a PLD basin are reproduced in the laboratory for infiltration tests. The empirical decay curve for sand-mix infiltration rate was derived from the laboratory data and then used to maximize the hydraulic efficiency through the subsurface filtering layers. In this study, it is recommended that a PLD system be designed with the optimal performance to consume the hydraulic head available and then evaluated using the prolonged drain time for potential standing water problems under various clogging conditions.
    • Download: (1.078Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Design of Two-Layered Porous Landscaping Detention Basin

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/59517
    Collections
    • Journal of Environmental Engineering

    Show full item record

    contributor authorJ. C. Y. Guo
    contributor authorS. M. Kocman
    contributor authorA. Ramaswami
    date accessioned2017-05-08T21:41:29Z
    date available2017-05-08T21:41:29Z
    date copyrightDecember 2009
    date issued2009
    identifier other%28asce%29ee%2E1943-7870%2E0000121.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/59517
    description abstractUnder the mandate of the Federal Clean Water Act, porous landscaping detention (PLD) has been widely used to increase on-site infiltration. A PLD system consists of a surface storage basin and subsurface filtering layers. The major design parameters for a PLD system are the infiltration rate on the land surface and the seepage rate through the subsurface medium. A low infiltration rate leads to a sizable storage basin while a high infiltration rate results in standing water if the subsurface seepage does not sustain the surface loading. In this study, the design procedure of a PLD basin is revised to take both detention flow hydrology and seepage flow hydraulics into consideration. The design procedure begins with the basin sizing according to the on-site water quality control volume. The ratio of design infiltration rate to sand-mix hydraulic conductivity is the key factor to select the thickness of sand-mix layer underneath a porous bed. The total filtering thickness for both sand-mix and gravel layers is found to be related to the drain time and infiltration rate. The recommended sand-mix and granite gravel layers underneath a PLD basin are reproduced in the laboratory for infiltration tests. The empirical decay curve for sand-mix infiltration rate was derived from the laboratory data and then used to maximize the hydraulic efficiency through the subsurface filtering layers. In this study, it is recommended that a PLD system be designed with the optimal performance to consume the hydraulic head available and then evaluated using the prolonged drain time for potential standing water problems under various clogging conditions.
    publisherAmerican Society of Civil Engineers
    titleDesign of Two-Layered Porous Landscaping Detention Basin
    typeJournal Paper
    journal volume135
    journal issue12
    journal titleJournal of Environmental Engineering
    identifier doi10.1061/(ASCE)EE.1943-7870.0000113
    treeJournal of Environmental Engineering:;2009:;Volume ( 135 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian