Enhanced Surface Cooling as an Alternative for Thermal DischargesSource: Journal of Environmental Engineering:;2009:;Volume ( 135 ):;issue: 012Author:Daniel G. MacDonald
DOI: 10.1061/(ASCE)EE.1943-7870.0000090Publisher: American Society of Civil Engineers
Abstract: Excess heat is an unavoidable by-product of electricity generation from fossil and nuclear fuels. In most cases, excess heat is transferred to a cooling water stream and discharged to a local receiving water body, or processed through on-site cooling towers. In many cases existing discharges are potentially responsible for significant ecological impacts, and regulatory authorities are mandating the construction of cooling towers, often at significant expense. Most existing cooling water discharges are designed to reduce excess temperatures through rapid dilution. Enhanced surface cooling is an alternative approach which involves the development of a thin surface plume, while limiting mixing of the discharge with ambient waters. This process encourages rapid transfer of heat to the atmosphere while limiting impacts to sensitive benthic environments and most of the volume of the receiving water body. This discharge approach may be particularly effective for receiving water bodies which have limited natural flushing, such as enclosed bays, estuaries, reservoirs and some river environments. A preliminary case study of a thermal discharge into Mt. Hope Bay (Massachusetts/Rhode Island) is discussed.
|
Collections
Show full item record
| contributor author | Daniel G. MacDonald | |
| date accessioned | 2017-05-08T21:41:26Z | |
| date available | 2017-05-08T21:41:26Z | |
| date copyright | December 2009 | |
| date issued | 2009 | |
| identifier other | %28asce%29ee%2E1943-7870%2E0000098.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/59491 | |
| description abstract | Excess heat is an unavoidable by-product of electricity generation from fossil and nuclear fuels. In most cases, excess heat is transferred to a cooling water stream and discharged to a local receiving water body, or processed through on-site cooling towers. In many cases existing discharges are potentially responsible for significant ecological impacts, and regulatory authorities are mandating the construction of cooling towers, often at significant expense. Most existing cooling water discharges are designed to reduce excess temperatures through rapid dilution. Enhanced surface cooling is an alternative approach which involves the development of a thin surface plume, while limiting mixing of the discharge with ambient waters. This process encourages rapid transfer of heat to the atmosphere while limiting impacts to sensitive benthic environments and most of the volume of the receiving water body. This discharge approach may be particularly effective for receiving water bodies which have limited natural flushing, such as enclosed bays, estuaries, reservoirs and some river environments. A preliminary case study of a thermal discharge into Mt. Hope Bay (Massachusetts/Rhode Island) is discussed. | |
| publisher | American Society of Civil Engineers | |
| title | Enhanced Surface Cooling as an Alternative for Thermal Discharges | |
| type | Journal Paper | |
| journal volume | 135 | |
| journal issue | 12 | |
| journal title | Journal of Environmental Engineering | |
| identifier doi | 10.1061/(ASCE)EE.1943-7870.0000090 | |
| tree | Journal of Environmental Engineering:;2009:;Volume ( 135 ):;issue: 012 | |
| contenttype | Fulltext |