    Sensitivity of Load Distribution in Light-Framed Wood Roof Systems due to Typical Modeling Parameters

    Source: Journal of Performance of Constructed Facilities:;2013:;Volume ( 027 ):;issue: 003
    Author:
    Ranjith
    ,
    Shivarudrappa
    ,
    Bryant G.
    ,
    Nielson
    DOI: 10.1061/(ASCE)CF.1943-5509.0000323
    Publisher: American Society of Civil Engineers
    Abstract: Because failure of roof systems in past high wind events has demonstrated the consequences of not maintaining a continuous load path from the roof to the foundation, many studies have been conducted to better understand this load path, including how loads are distributed in the system. The current study looks to add to the current knowledge of the vertical load path by focusing on uplift loads and by considering the sensitivity of different modeling parameters. This is done by developing and assessing load influence coefficient contours for various roof-to-wall (RTW) connections. An analytical model of a light-framed wood structure using finite-element software is developed. The model has a gable roof system comprised of fink trusses and is modeled in a highly detailed fashion including the explicit modeling of each connector/nail in the system. The influence coefficient plots indicate that the distribution of loads is indeed sensitive to the overall stiffness of RTW connections but is not overly sensitive to their relative stiffnesses. This was investigated by looking at cases where all connections have the same stiffness and cases where they can have different stiffnesses. However, the relative stiffness begins to have a larger impact as they begin to soften because of yielding. Furthermore, the stiffness of the sheathing connectors did not appear to have much of an impact on the distribution of load, but the sheathing stiffness itself did have a notable impact.
    • Download: (1.606Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Sensitivity of Load Distribution in Light-Framed Wood Roof Systems due to Typical Modeling Parameters

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/57924
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorRanjith
    contributor authorShivarudrappa
    contributor authorBryant G.
    contributor authorNielson
    date accessioned2017-05-08T21:37:42Z
    date available2017-05-08T21:37:42Z
    date copyrightJune 2013
    date issued2013
    identifier other%28asce%29cf%2E1943-5509%2E0000329.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/57924
    description abstractBecause failure of roof systems in past high wind events has demonstrated the consequences of not maintaining a continuous load path from the roof to the foundation, many studies have been conducted to better understand this load path, including how loads are distributed in the system. The current study looks to add to the current knowledge of the vertical load path by focusing on uplift loads and by considering the sensitivity of different modeling parameters. This is done by developing and assessing load influence coefficient contours for various roof-to-wall (RTW) connections. An analytical model of a light-framed wood structure using finite-element software is developed. The model has a gable roof system comprised of fink trusses and is modeled in a highly detailed fashion including the explicit modeling of each connector/nail in the system. The influence coefficient plots indicate that the distribution of loads is indeed sensitive to the overall stiffness of RTW connections but is not overly sensitive to their relative stiffnesses. This was investigated by looking at cases where all connections have the same stiffness and cases where they can have different stiffnesses. However, the relative stiffness begins to have a larger impact as they begin to soften because of yielding. Furthermore, the stiffness of the sheathing connectors did not appear to have much of an impact on the distribution of load, but the sheathing stiffness itself did have a notable impact.
    publisherAmerican Society of Civil Engineers
    titleSensitivity of Load Distribution in Light-Framed Wood Roof Systems due to Typical Modeling Parameters
    typeJournal Paper
    journal volume27
    journal issue3
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)CF.1943-5509.0000323
    treeJournal of Performance of Constructed Facilities:;2013:;Volume ( 027 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian