    Performance of Metal-Plated Wood Joints Exposed to Periods of Soaking Moisture

    Source: Journal of Performance of Constructed Facilities:;2012:;Volume ( 026 ):;issue: 006
    Author:
    Primus V.
    ,
    Mtenga
    ,
    Kamal S.
    ,
    Tawfiq
    ,
    Michelle
    ,
    Rambo-Roddenberry
    DOI: 10.1061/(ASCE)CF.1943-5509.0000271
    Publisher: American Society of Civil Engineers
    Abstract: Metal-plated wood truss systems may be rained upon during the construction phase, resulting in the soaking of the connections. In this paper, the results of an investigation of the behavior of metal-plated wood joints subjected to periods of soaking are presented. The wetting regimes included (1) 4-h shower, (2) alternating cycles of a period of shower wetting followed by a period of no shower, and (3) 24-h soaking in a water tank. Results of tests conducted after wetting and after wet-dry cycles were compared with results of dry control tests. The results show the wet joints lost over 40% of their load-carrying capacity in all three wetting regimes. Upon drying, the strength loss was about 10%. Likewise, the stiffness of the joints deteriorated, with stiffness loss ranging from 12 to 37%. In contrast to the load-carrying capacities, there were insignificant recoveries in joint stiffness upon the drying of the specimen, with additional loss of stiffness during the drying process in one of the groups investigated. The results of this study suggest the need to warn against severe wetting or to compensate for this probability of occurrence in truss design standards.
    • Download: (77.22Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Performance of Metal-Plated Wood Joints Exposed to Periods of Soaking Moisture

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/57868
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorPrimus V.
    contributor authorMtenga
    contributor authorKamal S.
    contributor authorTawfiq
    contributor authorMichelle
    contributor authorRambo-Roddenberry
    date accessioned2017-05-08T21:37:36Z
    date available2017-05-08T21:37:36Z
    date copyrightDecember 2012
    date issued2012
    identifier other%28asce%29cf%2E1943-5509%2E0000274.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/57868
    description abstractMetal-plated wood truss systems may be rained upon during the construction phase, resulting in the soaking of the connections. In this paper, the results of an investigation of the behavior of metal-plated wood joints subjected to periods of soaking are presented. The wetting regimes included (1) 4-h shower, (2) alternating cycles of a period of shower wetting followed by a period of no shower, and (3) 24-h soaking in a water tank. Results of tests conducted after wetting and after wet-dry cycles were compared with results of dry control tests. The results show the wet joints lost over 40% of their load-carrying capacity in all three wetting regimes. Upon drying, the strength loss was about 10%. Likewise, the stiffness of the joints deteriorated, with stiffness loss ranging from 12 to 37%. In contrast to the load-carrying capacities, there were insignificant recoveries in joint stiffness upon the drying of the specimen, with additional loss of stiffness during the drying process in one of the groups investigated. The results of this study suggest the need to warn against severe wetting or to compensate for this probability of occurrence in truss design standards.
    publisherAmerican Society of Civil Engineers
    titlePerformance of Metal-Plated Wood Joints Exposed to Periods of Soaking Moisture
    typeJournal Paper
    journal volume26
    journal issue6
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)CF.1943-5509.0000271
    treeJournal of Performance of Constructed Facilities:;2012:;Volume ( 026 ):;issue: 006
    contenttypeFulltext