YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Composites for Construction
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Composites for Construction
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Axial Capacity of Circular Concrete Columns Reinforced with GFRP Bars and Spirals

    Source: Journal of Composites for Construction:;2014:;Volume ( 018 ):;issue: 001
    Author:
    Mohammad Z. Afifi
    ,
    Hamdy M. Mohamed
    ,
    Brahim Benmokrane
    DOI: 10.1061/(ASCE)CC.1943-5614.0000438
    Publisher: American Society of Civil Engineers
    Abstract: Several codes and design guidelines are now available for the design of concrete structures reinforced with fiber-reinforced polymer (FRP) bars under flexural and shear loads. Yet, because of a lack of research, North American codes and design guidelines do not recommend using FRP bars as longitudinal reinforcement in columns to resist compressive stresses. This paper reports on 12 full-scale circular reinforced concrete (RC) columns that were tested under concentric axial loads. The columns were reinforced with longitudinal glass FRP (GFRP) bars and newly developed GFRP spirals. The 300-mm diameter columns were designed according to code requirements. The test parameters included reinforcement type (GFRP versus steel); longitudinal FRP reinforcement ratio; and the volumetric ratios, diameters, and spacing of spiral reinforcement. The test results indicated that the GFRP and steel RC columns behaved in a similar manner. The average load carried by the longitudinal GFRP bars ranged between 5% and 10% of the maximum load. The ductility and confinement efficiency can be better improved by using small GFRP spirals with closer spacing rather than larger diameters with greater spacing. Ignoring the contribution of GFRP bars in the design equation underestimated the maximum capacity of the tested specimens.
    • Download: (6.342Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Axial Capacity of Circular Concrete Columns Reinforced with GFRP Bars and Spirals

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/57584
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorMohammad Z. Afifi
    contributor authorHamdy M. Mohamed
    contributor authorBrahim Benmokrane
    date accessioned2017-05-08T21:37:04Z
    date available2017-05-08T21:37:04Z
    date copyrightFebruary 2014
    date issued2014
    identifier other%28asce%29cc%2E1943-5614%2E0000441.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/57584
    description abstractSeveral codes and design guidelines are now available for the design of concrete structures reinforced with fiber-reinforced polymer (FRP) bars under flexural and shear loads. Yet, because of a lack of research, North American codes and design guidelines do not recommend using FRP bars as longitudinal reinforcement in columns to resist compressive stresses. This paper reports on 12 full-scale circular reinforced concrete (RC) columns that were tested under concentric axial loads. The columns were reinforced with longitudinal glass FRP (GFRP) bars and newly developed GFRP spirals. The 300-mm diameter columns were designed according to code requirements. The test parameters included reinforcement type (GFRP versus steel); longitudinal FRP reinforcement ratio; and the volumetric ratios, diameters, and spacing of spiral reinforcement. The test results indicated that the GFRP and steel RC columns behaved in a similar manner. The average load carried by the longitudinal GFRP bars ranged between 5% and 10% of the maximum load. The ductility and confinement efficiency can be better improved by using small GFRP spirals with closer spacing rather than larger diameters with greater spacing. Ignoring the contribution of GFRP bars in the design equation underestimated the maximum capacity of the tested specimens.
    publisherAmerican Society of Civil Engineers
    titleAxial Capacity of Circular Concrete Columns Reinforced with GFRP Bars and Spirals
    typeJournal Paper
    journal volume18
    journal issue1
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)CC.1943-5614.0000438
    treeJournal of Composites for Construction:;2014:;Volume ( 018 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian