    Impact of Damper Stiffness and Damper Support Stiffness on the Efficiency of a Linear Viscous Damper in Controlling Stay Cable Vibrations

    Source: Journal of Bridge Engineering:;2014:;Volume ( 019 ):;issue: 004
    Author:
    Jennifer Anne
    ,
    Fournier
    ,
    Shaohong
    ,
    Cheng
    DOI: 10.1061/(ASCE)BE.1943-5592.0000562
    Publisher: American Society of Civil Engineers
    Abstract: Accurate prediction of optimum damper size and its corresponding maximum attainable modal damping ratio is essential for the design of a linear viscous damper to control cable vibrations on cable-stayed bridges. The stiffness within the damper and the damper support would affect both the required damper size and the resulting equivalent modal damping ratio of the damped cable and thus influence the damper efficiency. An experimental study on a cable-damper system is conducted to investigate the individual and the combined effects of damper stiffness and damper support stiffness on the performance of a linear viscous damper. A finite-element model of the corresponding cable-damper system is developed to verify the experimental results and further study these two parameters within the typical ranges of cable and damper properties used on real bridges. Results show that higher damper stiffness and/or lower damper support stiffness would have an adverse impact on damper performance. Increasing the stiffness of a damper and/or its support would result in a larger optimum damper size. However, the maximum attainable damping ratio would decrease with larger damper stiffness but increase if the support is more rigid. To facilitate practical design, a set of asymptotic relationships has been proposed, of which the optimum damper size and the maximum achievable damping ratio are expressed concisely as functions of nondimensional damper properties in terms of its location, stiffness, and support stiffness. Design examples are given to illustrate the various applications of the proposed refined damper design tool.
    • Download: (1.990Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Impact of Damper Stiffness and Damper Support Stiffness on the Efficiency of a Linear Viscous Damper in Controlling Stay Cable Vibrations

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/57114
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorJennifer Anne
    contributor authorFournier
    contributor authorShaohong
    contributor authorCheng
    date accessioned2017-05-08T21:35:59Z
    date available2017-05-08T21:35:59Z
    date copyrightApril 2014
    date issued2014
    identifier other%28asce%29be%2E1943-5592%2E0000566.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/57114
    description abstractAccurate prediction of optimum damper size and its corresponding maximum attainable modal damping ratio is essential for the design of a linear viscous damper to control cable vibrations on cable-stayed bridges. The stiffness within the damper and the damper support would affect both the required damper size and the resulting equivalent modal damping ratio of the damped cable and thus influence the damper efficiency. An experimental study on a cable-damper system is conducted to investigate the individual and the combined effects of damper stiffness and damper support stiffness on the performance of a linear viscous damper. A finite-element model of the corresponding cable-damper system is developed to verify the experimental results and further study these two parameters within the typical ranges of cable and damper properties used on real bridges. Results show that higher damper stiffness and/or lower damper support stiffness would have an adverse impact on damper performance. Increasing the stiffness of a damper and/or its support would result in a larger optimum damper size. However, the maximum attainable damping ratio would decrease with larger damper stiffness but increase if the support is more rigid. To facilitate practical design, a set of asymptotic relationships has been proposed, of which the optimum damper size and the maximum achievable damping ratio are expressed concisely as functions of nondimensional damper properties in terms of its location, stiffness, and support stiffness. Design examples are given to illustrate the various applications of the proposed refined damper design tool.
    publisherAmerican Society of Civil Engineers
    titleImpact of Damper Stiffness and Damper Support Stiffness on the Efficiency of a Linear Viscous Damper in Controlling Stay Cable Vibrations
    typeJournal Paper
    journal volume19
    journal issue4
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)BE.1943-5592.0000562
    treeJournal of Bridge Engineering:;2014:;Volume ( 019 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian