    Comparative Field Study of Cable Tension Measurement for a Cable-Stayed Bridge

    Source: Journal of Bridge Engineering:;2013:;Volume ( 018 ):;issue: 008
    Author:
    Soojin
    ,
    Cho
    ,
    Jinsuk
    ,
    Yim
    ,
    Sung Woo
    ,
    Shin
    ,
    Hyung-Jo
    ,
    Jung
    ,
    Chung-Bang
    ,
    Yun
    ,
    Ming L.
    ,
    Wang
    DOI: 10.1061/(ASCE)BE.1943-5592.0000421
    Publisher: American Society of Civil Engineers
    Abstract: Cable tension is one of the important indexes of cable integrity as well as bridge stability and can be measured by various tension measurement methods. In this study, three widely used methods (i.e., the lift-off test, electromagnetic sensor method, and vibration method) have been implemented for two multistrand cables of a cable-stayed bridge under construction. The test bridge is Hwamyung Bridge in Korea, which has a prestressed concrete box girder. The field tests are executed during the second tensioning stage just after the installation of the key segment. The tensions are estimated before and after tensioning the cable and 5 days later (i.e., after finishing the tensioning of all the cables). The tensions measured by the three methods are compared with the design tension of the tensioning stage, and all three methods show very good performance in accuracy with minimal difference. Their cost and difficulty are compared based on test experiences. Additionally, an improved vibration method is proposed by ignoring apparent negative bending stiffness identified from measurement errors and validated in this test by improving the accuracy.
    • Download: (668.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Comparative Field Study of Cable Tension Measurement for a Cable-Stayed Bridge

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/56970
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorSoojin
    contributor authorCho
    contributor authorJinsuk
    contributor authorYim
    contributor authorSung Woo
    contributor authorShin
    contributor authorHyung-Jo
    contributor authorJung
    contributor authorChung-Bang
    contributor authorYun
    contributor authorMing L.
    contributor authorWang
    date accessioned2017-05-08T21:35:32Z
    date available2017-05-08T21:35:32Z
    date copyrightAugust 2013
    date issued2013
    identifier other%28asce%29be%2E1943-5592%2E0000423.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/56970
    description abstractCable tension is one of the important indexes of cable integrity as well as bridge stability and can be measured by various tension measurement methods. In this study, three widely used methods (i.e., the lift-off test, electromagnetic sensor method, and vibration method) have been implemented for two multistrand cables of a cable-stayed bridge under construction. The test bridge is Hwamyung Bridge in Korea, which has a prestressed concrete box girder. The field tests are executed during the second tensioning stage just after the installation of the key segment. The tensions are estimated before and after tensioning the cable and 5 days later (i.e., after finishing the tensioning of all the cables). The tensions measured by the three methods are compared with the design tension of the tensioning stage, and all three methods show very good performance in accuracy with minimal difference. Their cost and difficulty are compared based on test experiences. Additionally, an improved vibration method is proposed by ignoring apparent negative bending stiffness identified from measurement errors and validated in this test by improving the accuracy.
    publisherAmerican Society of Civil Engineers
    titleComparative Field Study of Cable Tension Measurement for a Cable-Stayed Bridge
    typeJournal Paper
    journal volume18
    journal issue8
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)BE.1943-5592.0000421
    treeJournal of Bridge Engineering:;2013:;Volume ( 018 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace